喷砂大颗粒酸蚀种植体表面早期微生物与免疫参数的随机对照试验
结果显示仅常规表面1周时VEGF-α显著更高,两组在细菌载量、微生物多样性和其他免疫标志物上均无显著差异。结论认为两种表面在早期愈合期的免疫与微生物参数无差异。
要点
- 常规表面1周时VEGF-α显著高于改良亲水表面(p=0.018)
- 两组牙龈卟啉单胞菌和梭杆菌属最 prevalent,但qPCR细菌载量和微生物多样性无组间差异
核心结论
- 常规与改良亲水喷砂大颗粒酸蚀种植体表面在早期愈合期所评估的免疫与微生物参数间未检测到差异。
研究设计与样本
- 双中心、口内分口、随机对照临床试验,患者在不同象限各接受一枚试验(改良亲水表面)和一枚对照(常规表面)种植体。
- 植入时及第1、2、4周采集黏膜下样本,采用qPCR和16S rRNA测序分析;标志物与qPCR数据经log10转换后用一般线性模型分析,微生物组数据用Wilcoxon检验和PERMANOVA分析。
主要发现
- 常规表面在1周时VEGF-α水平显著更高(p=0.018)。
- 两组OPN和IL-10从基线至4周均显著升高。
- 牙龈卟啉单胞菌和梭杆菌属为最 prevalent 细菌,但qPCR细菌载量分析未发现表面间显著差异。
- 微生物组多样性在组间未观察到显著差异。
临床怎么用
- 在早期愈合期,改良亲水表面与常规喷砂大颗粒酸蚀表面在免疫和微生物参数上表现相当,临床选择时可综合考虑其他因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To compare microbiological and immunological parameters of two sandblasted, large-grit, acid-etched implant surfaces during the first 8 weeks of healing following implant placement. MATERIALS AND METHODS: A dual-center, split-mouth, randomized controlled clinical trial was conducted on patients receiving one test (modified hydrophilic surface) and one control (conventional surface) implant in different quadrants. Peri-implant crevicular fluid samples were collected at implant placement and at 1, 2, 4, and 8 weeks to assess biomarkers of inflammation (Interleukin [IL]-1β, IL-6, Tumor Necrosis Factor-α, IL-2), biomarkers of anti-inflammation (IL-4, IL-10), and biomarkers of bone metabolism (osteocalcin, osteopontin [OPN], and vascular endothelial growth factor-α [VEGF-α]). Additionally, submucosal samples were obtained at implant placement and at 1, 2, and 4 weeks and analyzed using quantitative polymerase chain reaction (qPCR) and 16S rRNA sequencing. Biomarkers and qPCR data were analyzed with a general linear model using log10-transformed values. Microbiome data were analyzed via Wilcoxon tests and PERMANOVA. RESULTS: Sixty patients were included in the 8-week analysis. VEGF-α levels were significantly higher at 1 week for the conventional surface (p = 0.018). OPN and IL-10 significantly increased from baseline to 4 weeks in both groups. Porphyromonas gingivalis and Fusobacterium species were the most prevalent bacteria; however, no significant differences were found between the surfaces in bacterial load analysis by qPCR. Additionally, no significant differences were observed between groups for microbiome diversity. CONCLUSION: No differences were detected between the conventional and the modified hydrophilic surfaces in the immunological and microbiological parameters assessed during early implant healing.
引用
- Vílchez B, Caneiro L, Lima C, et al. Early Microbiological and Immunological Parameters in Sandblasted, Large-Grit Acid-Etched Implant Surfaces: A Split Mouth Randomized Clinical Trial. Clin Oral Implants Res. 2025. PMID: 41137989. doi:10.1111/clr.70058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。