三种编码愈合基台设计对口内扫描精度影响的体外比较研究
该体外研究比较Bellatek Encode、iPhysio和Encode Emergence三种编码愈合基台(CHA)经口内扫描传递种植体三维位置的准确度和精确度。结果显示iPhysio组的3D平均偏差、RMS及2D准确度均显著优于其他两组(p<0.01),后牙区角度偏差更大,尤其Encode Emergence组。
要点
- iPhysio编码愈合基台的口内扫描准确度和重现性优于Bellatek Encode与Encode Emergence。
- 后牙区种植位点会放大角度偏差,基台几何形态影响数字印模保真度。
核心结论
- iPhysio编码愈合基台系统在尺寸准确度和重现性方面优于Bellatek Encode和Encode Emergence。
- 后牙种植位点会放大角度偏差,基台几何形态和种植位点对数字印模保真度有重要影响。
研究设计与样本
- 体外研究,使用含4枚内六角种植体(位点3.5、3.6、4.3、4.6)的下颌环氧树脂模型作为参考。
- 每种编码愈合基台以15 Ncm扭矩固定,在6个旋转方向下用口内扫描仪(Primescan)扫描。
- STL文件修剪后分为前、后段,与口外参考扫描(E4,3Shape)以最佳拟合算法配准,量化三维偏差、二维轴切片和角度差异。
- 准确度(平均偏差、RMS)和精确度(标准差)分析,组间比较采用Kruskal-Wallis检验与Mann-Whitney U事后检验(α=0.05)。
主要发现
- iPhysio组3D平均偏差(49.9 ± 95.4 µm)和RMS(91.5 ± 147.4 µm)显著低于Bellatek Encode和Encode Emergence组,精确度更优(72.4 ± 117.5 µm;p < 0.01)。
- 2D分析中,iPhysio组平均准确度(32.4 ± 87.6 µm)和RMS(76.6 ± 112.5 µm)最低(p < 0.01)。
- 分段分析显示后牙种植位点角度偏差更大,尤其Encode Emergence组。
关键数值与推荐
- iPhysio组3D平均偏差49.9 ± 95.4 µm,RMS 91.5 ± 147.4 µm,精确度72.4 ± 117.5 µm(p < 0.01)。
- iPhysio组2D平均准确度32.4 ± 87.6 µm,RMS 76.6 ± 112.5 µm(p < 0.01)。
- 编码愈合基台扭矩为15 Ncm,扫描旋转方向为6个。
临床怎么用
- 选择编码愈合基台时,iPhysio可能提供更高的口内扫描准确度和重现性。
- 后牙区种植位点扫描时需注意角度偏差可能增大,尤其使用Encode Emergence基台时。
局限性
- 本研究为体外研究,结果不能直接等同于临床口内扫描表现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the trueness and precision of three coded healing abutment (CHA) systems -Bellatek Encode (BE; ZimVie), iPhysio (IP; Lyra ETK), and Encode Emergence (EE; ZimVie)- for transferring 3D implant position via intraoral digital impressions in vitro. METHODS: A mandibular epoxy-resin model with four internal‑hex implants at sites 3.5, 3.6, 4.3, and 4.6. served as the reference. Each CHA was torqued to 15 Ncm and scanned in six rotational orientations using an intraoral scanner (Primescan, Dentsply Sirona). STL files were trimmed and divided into anterior and posterior segments. Scans were superimposed on an extraoral reference scan (E4, 3Shape) using a best-fit algorithm in Geomagic. Three-dimensional deviations, 2D axial slices, and angular discrepancies were quantified. Trueness (mean deviations, RMS) and precision (standard deviation) were analyzed. Intergroup comparisons were performed using the Kruskal-Wallis with Mann-Whitney U post hoc tests (α=0.05). RESULTS: Group IP exhibited significantly lower 3D mean deviation (49.9 ± 95.4 µm) and RMS (91.5 ± 147.4 µm) than groups BE and EE, and superior precision (72.4 ± 117.5 µm; p < 0.01). In 2D analyses, IP achieved the lowest mean trueness (32.4 ± 87.6 µm) and RMS (76.6 ± 112.5 µm) compared with the other groups (p < 0.01). Segmental analyses revealed greater angular deviations at posterior implant sites, particularly for group EE. CONCLUSIONS: The IP CHA system demonstrates superior dimensional accuracy and reproducibility compared with BE and EE. Posterior implant position amplify angular deviations, emphasizing the critical role of abutment geometry and implant positioning digital-impression fidelity.