种植支持式固定义齿边缘不密合对种植体周围骨水平的影响:回顾性定量分析
该回顾性研究分析了301例患者505枚种植体在负载10.6±0.7年后,种植支持式修复体边缘间隙与种植体周围骨水平的关系。结果显示无间隙组的种植体肩台至骨嵴顶距离(DIB)显著低于有间隙组,间隙≥0.1 mm组DIB最高,且垂直间隙每增加0.1 mm,DIB增加0.08 mm。吸烟和牙周炎病史是DIB增大的独立危险因素。
要点
- 修复体边缘无间隙者DIB显著低于有间隙者,间隙≥0.1 mm时DIB最高。
- 垂直间隙每增加0.1 mm,DIB平均增加0.08 mm。
- 吸烟和牙周炎病史是种植体周围骨水平升高的独立危险因素。
核心结论
- 种植支持式修复体边缘不密合影响种植体周围骨稳定性,间隙≥0.1 mm与更高的DIB相关。
- 吸烟和牙周炎是DIB增大的独立危险因素。
研究设计与样本
- 回顾性定量分析,纳入接受种植支持式修复体进行缺牙修复的受试者。
- 共分析301例患者和505枚种植体,随访时间为10.6±0.7年。
- 负载10年后拍摄标准化口内根尖片,评估种植体肩台至骨嵴顶最冠方点的放射学距离(DIB)。
- 修复体边缘间隙分为无间隙和有间隙,垂直维度分为0 mm、>0-<0.1 mm和≥0.1 mm。
- 采用多变量线性混合效应模型控制潜在混杂因素。
主要发现
- 无间隙修复体的DIB为3.22±0.8 mm,显著低于有间隙修复体的3.43±0.6 mm(p=0.001)。
- 间隙≥0.1 mm组的DIB为3.45±0.7 mm,显著高于间隙>0且<0.1 mm组的3.36±0.5 mm(p=0.001)和无间隙组的3.22±0.7 mm(p=0.001)。
- 垂直骨嵴间隙每增加0.1 mm,DIB显著增加0.08 mm(p=0.03)。
- 吸烟和牙周炎病史是DIB增大的独立危险因素。
关键数值与推荐
- 修复体边缘垂直间隙分类阈值:0 mm、>0-<0.1 mm、≥0.1 mm。
- 间隙≥0.1 mm与显著更高的DIB相关(3.45±0.7 mm)。
- 垂直间隙每增加0.1 mm,DIB增加0.08 mm(p=0.03)。
临床怎么用
- 临床制作种植支持式修复体时应尽量实现边缘无间隙,避免垂直间隙≥0.1 mm。
- 对吸烟和/或有牙周炎病史的种植修复患者,应加强种植体周围骨水平的监测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the impact of the marginal fit of implant-supported prostheses (ISP) on peri-implant bone levels. Additionally, the study aimed to determine a clinically relevant threshold for the radiographic vertical misfit gap at the ISP, when present, and to identify potential risk factors associated with changes in bone levels. METHODS: This study involved subjects who received ISPs for tooth replacement therapy. Standardized intraoral periapical radiographs were taken 10 years after loading to assess the radiographic distance between the implant shoulder and the most coronal point of crestal bone (DIB). ISP marginal gaps were categorized as no gap or gap, with vertical dimensions categorized as 0 mm, > 0- < 0.1 mm, and ≥ 0.1 mm. A multivariable linear mixed-effect model was applied to control for potential confounders. RESULTS: A total of 301 patients and 505 implants with a 10.6 ± 0.7 years follow-up were analyzed. ISPs without gaps exhibited statistically significantly lower DIB values (3.22 ± 0.8 mm) than those with gaps (3.43 ± 0.6 mm; p = 0.001). Gaps ≥ 0.1 mm were associated with statistically significantly higher DIB values (3.45 ± 0.7 mm; p = 0.001) compared with gaps between > 0 and < 0.1 mm (3.36 ± 0.5 mm; p = 0.001), or no gaps (3.22 ± 0.7 mm; p = 0.001). Each increment of 0.1 mm in the vertical crestal gap corresponded to a significant increase in DIB values (0.08 mm; p = 0.03). Finally, smoking and a history of periodontitis were independent risk factors for increased DIB. CONCLUSIONS: Marginal misfit of ISP affects peri-implant bone stability, with gaps ≥ 0.1 mm linked to higher DIB. Smoking and periodontitis are independent risk factors for increased DIB.
引用
- Couso-Queiruga E, Ramseier CA, Chappuis V, et al. Impact of Marginal Misfit in Implant-Supported Fixed Dental Prostheses on Peri-Implant Bone Levels: A Retrospective Quantitative Analysis. Clin Oral Implants Res. 2025. PMID: 41046331. doi:10.1111/clr.70053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。