AI与人工设计在动态导航牙髓显微手术路径规划中的准确性与设计时间比较
AI组根端切除长度偏差显著更小,但根端切除角度偏差显著更大,设计时间显著更短。结论认为AI路径设计可减少人工干预并快速提供准确结果。
要点
- AI组根端切除长度偏差显著小于人工组(p=0.029)。
- AI组根端切除角度偏差显著大于人工组(p<0.001)。
- AI组设计时间显著短于人工组(p<0.001)。
核心结论
- AI手术路径设计可减少人工干预,为临床提供省时且准确的结果。
- AI与动态导航辅助牙髓显微手术结合可能促进更自主的手术流程。
研究设计与样本
- 使用DCARE导航系统(v3.2)和AutoCAD 2023评估准确性,设计时间从CBCT数据导入至路径设计完成。
- 采用Mann-Whitney U检验比较组间准确性与设计时间,秩基于ANCOVA评估牙位、颌骨类型和根数的影响,显著性水平p<0.05。
主要发现
- AI组根端切除长度偏差为0.01 [0.01, 0.02] mm,人工组为0.02 [0.01, 0.03] mm,差异显著(p=0.029)。
- AI组根端切除角度偏差为3.48 [1.01, 7.48],人工组为0.35 [0.16, 0.73],差异显著(p<0.001)。
- 起始偏差、终点偏差、角度偏差在牙位、颌骨类型或根数间均无显著差异。
- AI组设计时间为55 [21, 74] s,人工组为379 [215, 553] s,差异显著(p<0.001)。
临床怎么用
- AI路径设计可显著缩短设计时间,适合临床快速规划。
- 需关注AI在根端切除角度偏差上的劣势,临床应用中应加以评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To compare the accuracy and design time of artificial intelligence (AI)-generated and manually designed (MD) surgical pathways for osteotomies and root-end resections in dynamic navigation (DN)-aided endodontic microsurgery (EMS). METHODOLOGY: Fifty-one surgical pathways were analysed, each planned using both AI and MD methodologies. Accuracy was assessed using the DCARE Navigation System (v3.2, MedNav Ltd) and AutoCAD (2023, Autodesk Inc.), evaluating five parameters: start deviation, end deviation, angular deviation, root-end resection length deviation, and root-end resection angulation deviation. Design time was measured from the point of CBCT dataset import to the finalisation of the surgical pathway design. Mann-Whitney U test was used to compare the accuracy and design time of the AI and MD groups, whereas the rank-based ANCOVA was used to assess deviations according to tooth type, jaw type, and root number. Statistical significance was set at p < 0.05. RESULTS: Compared with the MD group, the AI group exhibited significantly smaller root-end resection length deviations (AI: 0.01 [0.01, 0.02] mm; MD: 0.02 [0.01, 0.03] mm; p = 0.029) but significantly larger root-end resection angulation deviations (AI: 3.48 [1.01, 7.48]; MD: 0.35 [0.16, 0.73]; p < 0.001). There were no significant differences in the start deviation, end deviation, angular deviation, root-end resection length deviation, or root-end resection angulation deviation across tooth type, jaw type, or root number. The design time was significantly shorter in the AI group than in the MD group (55 [21, 74] s vs. 379 [215, 553] s; p < 0.001). CONCLUSIONS: A clinically operational AI-based surgical path design approach is capable of minimising manual interventions and delivering time-efficient, accurate results for clinical use. The integration of AI with DN-aided EMS may contribute to the development of increasingly autonomous surgical procedures.
引用
- Chen C, Zhang X, Qin L, et al. Comparative Analysis of AI-Generated and Manually Designed Approaches in Accuracy and Design Time for Surgical Path Planning of Dynamic Navigation-Aided Endodontic Microsurgery: A Retrospective Study. Int Endod J. 2025. PMID: 41035305. doi:10.1111/iej.70045