牙髓治疗后进入腔清洁技术疗效的随机临床研究
结果显示空气喷砂、乙醇饱和微刷(临床可接受清洁度)、乙醇饱和棉球+空气抛光等组封闭剂覆盖面积减少率最高,均显著优于干棉球等低效方法。
要点
- 空气喷砂、乙醇微刷(临床可接受清洁度)和乙醇棉球+空气抛光清除残留封闭剂效果最佳。
- 干棉球、乙醇棉球5秒和乙醇微刷5秒的清洁效果显著较低。
- 机械辅助清洁(空气抛光/喷砂)是临床最可靠的进入腔清洁策略。
核心结论
- 空气喷砂、乙醇饱和微刷(临床可接受清洁度)、乙醇饱和棉球+空气抛光及乙醇饱和棉球(临床可接受清洁度)在去除进入腔残留封闭剂方面效果优越。
主要发现
- 所有清洁方案均较基线显著降低封闭剂覆盖面积(P < .05)。
- 空气喷砂组封闭剂覆盖面积减少96.1%,乙醇饱和微刷(临床可接受清洁度)组减少93.9%,乙醇饱和棉球+空气抛光组减少92.8%,三组间无显著差异(P > .05)。
- 上述三组清洁效能显著高于乙醇饱和微刷(5秒)组(36.1%)、干棉球组(26.4%)和乙醇饱和棉球(5秒)组(17.7%)(P < .05)。
关键数值与推荐
- 以像素分析计算封闭剂覆盖面积(SCA),统计方法包括Shapiro-Wilk检验、配对样本t检验、Kruskal-Wallis检验和Mann-Whitney U检验,P < .05为显著。
临床怎么用
- 临床可优先采用空气喷砂、乙醇饱和微刷(临床可接受清洁度)或乙醇饱和棉球+空气抛光清洁根管充填后的进入腔。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This randomized clinical study aimed to evaluate the efficacy of different postendodontic access cavity cleaning techniques in removing residual epoxy resin-based sealer from the pulp chamber floor following root canal obturation. METHODS: Seventy patients requiring root canal treatment in maxillary first molars were randomly assigned to 7 groups (n = 10) according to the cleaning protocol: dry cotton pellet, ethanol-saturated cotton pellet (5 seconds), ethanol-saturated cotton pellet (clinically acceptable cleanliness), ethanol-saturated cotton pellet + air polishing, ethanol-saturated microbrush (5 seconds), ethanol-saturated microbrush (clinically acceptable cleanliness) and air abrasion. After obturation with gutta-percha and AH Plus sealer, standardized macro photographs were taken before and after cleaning procedures. The sealer-covered area (SCA) was calculated using Adobe Photoshop based on pixel analysis. Statistical analyses included the Shapiro-Wilk, Paired samples t, Kruskal-Wallis and Mann-Whitney U tests. A P value of <.05 was considered statistically significant. RESULTS: All cleaning protocols significantly reduced SCA values compared to baseline (P < .05). The highest SCA reductions were observed in the air abrasion (96.1%), ethanol-saturated microbrush (clinically acceptable cleanliness) (93.9%), ethanol-saturated cotton pellet + air polishing (92.8%) groups, with no significant differences among them (P > .05). These groups showed significantly higher cleaning efficacy compared to the ethanol-saturated microbrush (5 seconds) (36.1%), dry cotton pellet (26.4%), and the ethanol-saturated cotton pellet (5 seconds) (17.7%) groups (P < .05). CONCLUSIONS: Among the evaluated methods, air abrasion, ethanol-saturated microbrush (clinically acceptable cleanliness), ethanol-saturated cotton pellet + air polishing and ethanol-saturated cotton pellet (clinically acceptable cleanliness) demonstrated superior effectiveness in removing residual sealer from the access cavity. Although no statistically significant differences were observed, application of microbrush and mechanically assisted cleaning techniques, including air polishing and air abrasion, emerged as the most reliable and effective cleaning strategies for clinical practice.
引用
- Karadayi A, Irem Altintas E, Bayraktar ET, et al. Efficacy of Post-Endodontic Access Cavity Cleaning Techniques: A Randomized Clinical Study. J Endod. 2025. PMID: 41135740. doi:10.1016/j.joen.2025.10.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。