文献速递牙体牙髓病

机器人引导开髓洞形预备处理钙化根管的精度:体外研究

Accuracy of Robot-Guided Access Cavity Preparation in Managing Calcified Canals: An In Vitro Study.
PubMed 文献 · Int Endod J · 2025-10-10

本研究用3个3D打印下颌钙化根管模型,比较机器人、静态导板与动态导航引导开髓洞形预备的精度。机器人组与静态导板组全部12个根管均被定位,动态导航组12个中定位10个并有2个根管穿孔;机器人组与静态导板组精度无显著差异,但根尖偏移与角度偏移显著低于动态导航组。

要点

  • 机器人引导与静态导板引导开髓定位钙化根管精度相当
  • 机器人组根尖偏移和角度偏移显著低于动态导航组
  • 动态导航组12个根管中2个出现根管穿孔,需谨慎使用

核心结论

  • 机器人系统引导开髓洞形预备的精度与静态导板相当,在钙化根管引导开髓中显著优于动态导航。

研究设计与样本

  • 体外研究,采用3个3D打印下颌钙化根管模型,分机器人组、静态导板组和动态导航组进行开髓洞形预备。
  • 主要结局为规划与实际开髓路径间的冠部偏移、根尖偏移和角度偏移,并确认根管是否被定位。
  • 统计分析采用单因素方差分析、Tukey事后检验和多层线性回归模型,显著性水平设为0.05。

主要发现

  • 机器人组和静态导板组全部12个根管均被定位,动态导航组12个中定位10个,2个导致根管穿孔。
  • 机器人组开髓精度与静态导板组相比无显著差异(p > 0.05)。
  • 机器人组根尖偏移和角度偏移结果显著低于动态导航组(p < 0.05)。

临床怎么用

  • 对于钙化根管的引导开髓,机器人系统可作为与静态导板精度相当的方案,并可能优于动态导航。

局限性

  • 作者指出需进一步临床研究确认这些初步发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the accuracy of guided access cavity preparation in calcified canals using a robotic system, compared to static and dynamic guided methods. METHODOLOGY: Three 3D-printed mandibular models presenting with pulp canal obliteration were allocated into three groups for robot, static and dynamic-guided access cavity preparations. The primary outcomes measured were the coronal deviation, apical deviation and angular deviation between the planned and actual paths of access cavity preparation. Additionally, all access cavities were confirmed to determine whether the canal was located. The data were analysed using the one-way analysis of variance (ANOVA), Tukey's post hoc test and multilevel linear regression models. The significance level was set at 0.05. RESULTS: All canals (n = 12) in the robot-guided and static-guided groups were located. In the dynamic guided group, a total of 10 out of 12 canals were found, with 2 resulting in root perforations. The accuracy of access cavity preparation using a robotic system showed no significant difference compared to the static-guided group (p > 0.05). However, the apical and angular deviation results were significantly lower in the robot-guided group than the dynamic-guided group (p < 0.05). CONCLUSIONS: The robotic system exhibited comparable accuracy to the static guide, whereas it significantly outperformed dynamic navigation in terms of guided access cavity preparation for calcified root canals. However, further clinical studies are needed to confirm these preliminary findings.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Liu Y, Liu C, Bai S, et al. Accuracy of Robot-Guided Access Cavity Preparation in Managing Calcified Canals: An In Vitro Study. Int Endod J. 2025. PMID: 41070592. doi:10.1111/iej.70049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。