文献速递口腔修复与种植

人工智能与牙科技师全冠设计形态的对比分析

Comparative analysis of full crown morphology designed by artificial intelligence and dental technicians.
PubMed 文献 · J Dent · 2025-09-23

结果显示AI全冠在颊舌径和近远中径上更接近天然牙,但两者颊尖角均大于天然牙,且AI未能准确复制功能尖磨耗面。

要点

  • AI全冠颊舌径与近远中径与天然牙无显著差异,技师全冠显著偏小。
  • AI与技师全冠颊尖角均大于天然牙,舌尖角组间无显著差异。
  • AI未能准确复制功能尖磨耗面,技师设计倾向于过度补偿。

核心结论

  • AI系统可一定程度复现与经验丰富技师相当的全冠整体形态,但在复制功能磨耗面方面仍有限。

研究设计与样本

  • 每个病例由经验丰富牙科技师和AI系统独立设计全冠,比较天然牙、技师全冠和AI全冠的形态特征。
  • 采用单因素方差分析及LSD事后检验,显著性水平α=0.05。

主要发现

  • AI全冠颊尖角为56.2°±5.1°,技师全冠为57.5°±6.3°,均大于天然牙的45.7°±4.9°(p<0.05)。
  • 舌尖角组间比较p=0.434、0.607、0.787,无显著差异。
  • AI全冠颊舌径与天然牙无显著差异(p=0.094),技师全冠显著小于AI全冠(p=0.034)和天然牙(p=0.044)。
  • AI全冠近远中径与天然牙无显著差异(p=0.223),技师全冠与两组均有显著差异(p=0.047、0.002)。
  • AI全冠3D偏差为0.43±0.07,技师全冠为0.48±0.06,差异无统计学意义(p=0.089)。

临床怎么用

  • AI可作为全冠设计的实用高效工具,有望提高修复体设计一致性并减少手工工作量。
  • 在功能形态细节被充分改进前,AI全冠设计尚不能完全替代技师对功能磨耗面的处理。

局限性

  • 样本量较小,仅纳入下颌右侧第二前磨牙。
  • 功能尖磨耗和咬合接触基于形态观察和虚拟咬合纸条件下的视觉分析进行定性评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the morphological characteristics of full crowns designed by an experienced dental technician and a data-driven artificial intelligence (AI) system, with particular attention to their similarity to natural teeth. METHODS: Twelve digital casts, including mandibular right second premolars, were collected, three-dimensional (3D) printed, and prepared by an experienced dentist. For each case, two crowns were independently designed by an experienced dental technician (ET) and the AI system. Morphological characteristics, including buccal and lingual cusp angle, buccal-lingual diameter, mesial-distal diameter, functional cusp wear facets, 3D similarity, and occlusal contact point counts, were compared among natural teeth, ET crowns, and AI crowns. Functional cusp wear and occlusal contacts were evaluated qualitatively, based on morphological observation and visual analysis under virtual articulating paper conditions. Statistical analysis was performed using one-way analysis of variance (ANOVA) followed by least significant difference (LSD) post-hoc testing, with the significance level set at α = 0.05. RESULTS: Both AI crowns (56.2° ± 5.1°) and ET crowns (57.5° ± 6.3°) exhibited larger buccal cusp angles than natural teeth (45.7° ± 4.9°) (p < 0.05), while no significant differences were found in lingual cusp angles among the groups (p = 0.434, 0.607, 0.787). The buccal-lingual diameter of AI crowns closely matched natural teeth (p = 0.094), whereas ET crowns were significantly smaller than both AI crowns (p = 0.034) and natural teeth (p = 0.044). The mesial-distal diameter of AI crowns also showed no significant difference from natural teeth (p = 0.223), while ET crowns differed significantly from both groups (p = 0.047, 0.002). Although AI crowns exhibited slightly lower 3D discrepancy (0.43 ± 0.07) than ET crowns (0.48 ± 0.06), the difference was not statistically significant (p = 0.089). AI did not accurately reproduce functional cusp wear facets, whereas technician designs tended to overcompensate. Occlusal contact counts showed no significant differences among groups. CONCLUSIONS: AI systems can reproduce overall crown morphology to a degree comparable with experienced technicians but remain limited in replicating functional wear facets. CLINICAL IMPLICATIONS: AI offers a practical and efficient tool for crown design, with potential to improve consistency and reduce manual workload in prosthodontics. However, further refinement is required before these systems can fully replicate functional morphological details for widespread clinical application.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Wang Y, Li Y, Xu M, et al. Comparative analysis of full crown morphology designed by artificial intelligence and dental technicians. J Dent. 2025. PMID: 40998103. doi:10.1016/j.jdent.2025.106131

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。