定量光诱导荧光技术在早期龋检测及树脂渗透治疗中的应用
本研究通过三个实验(各n=6)评估QLF在早期龋检测及树脂渗透治疗前后的适用性,以TMR和分光光度计为参照。结果表明,脱矿深度<200 µm时QLF检测准确且与TMR高度相关(r=-0.9938,p<0.05),可评估树脂渗透疗效;但树脂渗透后再次脱矿且深度>200 µm时QLF准确性显著下降。
要点
- 脱矿深度<200 µm时,QLF检测早期龋准确,与TMR相关性好(r=-0.9938)。
- QLF可有效评估树脂渗透治疗对早期龋的疗效。
- 树脂渗透后再次脱矿深度>200 µm时,QLF诊断准确性显著下降。
核心结论
- 脱矿深度<200 µm时,QLF可用于检测早期龋并评估其治疗效果。
- 树脂渗透治疗后再次脱矿且深度>200 µm时,QLF不适用于检测。
研究设计与样本
- 实验一:结合TMR与分光光度计分析,评估QLF检测早期龋病变深度的准确性(n=6)。
- 实验二:以树脂渗透治疗为代表,评估QLF评估早期龋疗效的能力(n=6)。
- 实验三:对治疗后早期龋进行再脱矿,评估QLF对更深病变的检测能力(n=6)。
主要发现
- 脱矿深度<200 µm时,QLF与分光光度计均准确,且与TMR结果相关性好(r=-0.9938,r=0.9776,p<0.05)。
- QLF与分光光度计检测均能有效反映树脂渗透治疗后的疗效。
- 树脂渗透后再次脱矿且病变深度>200 µm时,QLF诊断准确性显著下降,不如TMR和分光光度计精确。
临床怎么用
- 脱矿深度<200 µm的早期龋,可用QLF检测并评估树脂渗透治疗效果。
- 树脂渗透治疗后怀疑深部再脱矿(>200 µm)时,不宜单独依赖QLF,应结合TMR或分光光度计。
局限性
- 各实验样本量均为6,样本量小。
- 结论基于特定实验条件,外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this study is to explore the specific application scenarios of quantitative light-induced fluorescence (QLF) in detecting early caries before and after treatment, so as to provide more evidence for the clinical application of QLF. METHODS: (1) The accuracy of QLF in detecting the lesion depth of early caries was evaluated by combining transverse microradiography (TMR) and spectrophotometer analysis (n = 6). (2) Resin infiltration therapy was used as a representative method for the treatment of early caries to evaluate the ability of QLF in assessing the therapeutic effect on early caries (n = 6). (3) Re-demineralization of early caries after treatment was performed to evaluate the detection capability of QLF for deeper lesions (n = 6). RESULTS: In the detection of early caries, when the demineralization depth was <200 µm, both QLF and spectrophotometer analysis were accurate and correlated well with TMR results (r=-0.9938, r=0.9776, p < 0.05). In addition, both QLF and spectrophotometer detection could effectively reflect the therapeutic effect on early caries after resin infiltration treatment. However, when the early caries treated with infiltrative resin were re-demineralized and the lesion depth > 200 µm, the diagnostic accuracy of QLF for the re-demineralized early caries decreased significantly, which was not as precise as TMR and spectrophotometer analysis. CONCLUSION: When the demineralization depth is <200 µm, QLF can be used to detect early caries and evaluate the therapeutic effect on early caries. However, QLF is not suitable for detecting deep re-demineralized lesions exceeds 200 μm after resin infiltration treatment. CLINICAL SIGNIFICANCE: Timely diagnosis and treatment of early caries are very important in clinic. Exploring the specific applicability of QLF in detecting early caries before and after treatment is helpful to provide more evidence for its clinical application, which is of great significance for the prevention and treatment of caries.
引用
- Shi Y, Feng X, Li M, et al. Application of quantitative light-induced fluorescence technology in early caries detection and resin infiltration treatment. J Dent. 2025. PMID: 40914274. doi:10.1016/j.jdent.2025.106086
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。