文献速递口腔修复与种植

质子泵抑制剂使用与种植体周骨微结构的分形分析评估:回顾性病例对照研究

Evaluation of the Relationship Between Intake of Proton Pump Inhibitors and Peri-Implant Bone Microstructure by Using Fractal Analysis: A Retrospective Case-Control Study.
PubMed 文献 · Clin Oral Implants Res · 2025-08-25

本研究通过根尖片分形分析,回顾性匹配比较27例PPI使用者(87枚种植体)与27例非使用者(88枚种植体)的种植体周骨小梁模式。平均随访76.9个月,两组种植体存留率及边缘骨吸收无显著差异,但PPI组分形维数值显著低于非使用者(1.14 vs 1.19,p<0.01)。提示PPI使用可能对种植体周围骨代谢产生不利影响。

要点

  • PPI使用者种植体周骨小梁分形维数显著低于非使用者。
  • 两组种植体存留率及边缘骨吸收无显著差异。
  • 临床医生应关注PPI治疗患者颌骨骨小梁可能的变化。

核心结论

  • PPI使用可能对种植体周围骨代谢产生不利影响。

研究设计与样本

  • 回顾性匹配病例对照研究,纳入27例PPI使用者(87枚种植体)和27例非使用者(88枚种植体),共54例患者175枚种植体。
  • 按年龄、性别、吸烟状态、总随访时长及增骨手术史进行匹配。
  • 所有种植体为同一品牌,成分和表面处理相同。

主要发现

  • 平均随访76.9个月,PPI组3例种植体失败,非使用者组无失败(p>0.05)。
  • 两组边缘骨吸收值无显著差异(p>0.05)。
  • 末次随访平均分形维数值:PPI组1.14(0.07),非使用者组1.19(0.05),差异显著(p<0.01)。

临床怎么用

  • 对接受PPI治疗的患者进行种植治疗时,应警惕颌骨骨小梁可能的变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Proton pump inhibitors (PPIs) have been suggested to influence bone metabolism and osseointegration. This study aimed to assess the long-term effects of PPI usage on trabecular bone patterns around dental implants through fractal analysis of periapical radiographs. MATERIAL AND METHODS: This retrospective, matched case-control study analyzed a database of 27 PPI users (87 dental implants) and established a control group of 27 nonusers (88 dental implants), matching them by age, sex, smoking status, total follow-up duration, and history of augmentation procedures. The final study population included 54 patients with a total of 175 dental implants, all of which were from the same brand and identical in composition and surface treatment. The primary predictor variable was PPI use, while the outcome measures included implant survival rate, crestal bone loss (CBL), and fractal dimension (FD) values assessed on periapical radiographs. RESULTS: Three PPI users experienced implant failure during a mean follow-up period of 76.9 months, whereas no failures occurred in the nonuser group (p > 0.05). Similarly, no significant differences were observed in CBL values between the two groups (p > 0.05). However, the mean (standard deviation) FD values at the final follow-up were 1.14 (0.07) for PPI users and 1.19 (0.05) for nonusers, showing a significant difference (p < 0.01). CONCLUSIONS: The findings of this study suggest that PPI use may have a detrimental impact on bone metabolism surrounding dental implants. Clinicians should be vigilant regarding possible trabecular alterations in the jawbones of patients undergoing PPI therapy.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Urcan SR, Kuran A, Ankaralı DA, et al. Evaluation of the Relationship Between Intake of Proton Pump Inhibitors and Peri-Implant Bone Microstructure by Using Fractal Analysis: A Retrospective Case-Control Study. Clin Oral Implants Res. 2025. PMID: 40853030. doi:10.1111/clr.70032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。