文献速递口腔修复与种植牙周病

钛刷、壳聚糖刷与镍钛刷对钛种植体表面机械清创的表面特异性结果

Surface-specific outcomes of mechanical debridement with titanium, chitosan and nitinol brushes on titanium dental implant surfaces.
PubMed 文献 · J Dent · 2025-07-30

本研究评估钛刷、壳聚糖刷和镍钛刷对四种钛种植体表面(类OsseoSpeed®、类SLActive®、机加工和抛光)性能的影响。采用轮廓仪、接触角测量、SEM、EDX和XPS评估表面性能与化学。结果显示壳聚糖刷表面改变最小但刷毛快速磨损留下有机残留增加疏水性;钛刷和镍钛刷对粗糙表面形态改变更明显,并通过环境碳污染增加疏水性;抛光表面不受影响。

要点

  • 壳聚糖刷对种植体表面改变最小,但刷毛磨损快,有机残留增加表面疏水性。
  • 钛刷和镍钛刷对粗糙表面(类OsseoSpeed®和类SLActive®)形态和形貌改变更明显。
  • 所有组疏水性增加与碳污染相关;抛光表面对机械清创无变化。

核心结论

  • 壳聚糖刷表面改变最小但刷毛快速磨损留下有机残留增加疏水性。
  • 钛刷和镍钛刷导致更明显的表面改变,并通过清创过程中的环境碳污染增加疏水性。

研究设计与样本

  • 研究评估钛刷、壳聚糖刷和镍钛刷对四种钛种植体表面(类OsseoSpeed®、类SLActive®、机加工和抛光)的影响。
  • 采用轮廓仪、接触角测量、扫描电子显微镜(SEM)、能量色散X射线光谱(EDX)和X射线光电子能谱(XPS)评估表面性能和化学。

主要发现

  • SEM和轮廓仪显示钛刷和镍钛刷改变了粗糙的类OsseoSpeed®和类SLActive®表面的形态和形貌,对机加工表面影响较小。
  • 壳聚糖刷引起最小变化,但刷毛因物理磨损快速磨损,增加表面碳,EDX检测到并由XPS鉴定为有机材料。
  • XPS确认金属刷处理样本中的碳污染主要是环境来源。
  • 所有组观察到的疏水性增加与碳污染相关。
  • 抛光表面不受机械清创影响。

临床怎么用

  • 选择机械清创工具需平衡有效去除生物膜与对种植体表面性能的影响。
  • 种植体表面性能(形貌、形态、润湿性和表面化学)对细菌粘附和骨整合起关键作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Dental implants are susceptible to peri‑implant inflammation caused by bacterial biofilms, with surface properties playing a key role in bacterial adhesion and osseointegration. While mechanical debridement is essential for biofilm removal, consensus on the optimal tool remains limited. In this study, we evaluate the impact of a titanium, a chitosan and a nitinol brush on the surface properties of four titanium dental implant surfaces: OsseoSpeed®-like, SLActive®-like, machined, and polished. METHODS: Profilometry, contact angle measurements, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) were used to assess the surface properties and chemistry. RESULTS: SEM and profilometry revealed that the titanium and nitinol brushes altered the morphology and topography of the rough OsseoSpeed®-like and SLActive®-like surfaces, while these effects were less pronounced on machined surfaces. Conversely, the chitosan brush caused minimal changes, but its bristles wore down quickly by physical abrasion, increasing surface carbon as detected by EDX and identified by XPS as organic material. Conversely, XPS confirmed that carbon contamination in samples treated with metal brushes was primarily environmental. The increased hydrophobicity observed across all groups was linked to carbon contamination. Polished surfaces remained unaffected by mechanical debridement. CONCLUSIONS: The chitosan brush showed minimal surface alterations, but the rapid bristle wear left organic residues that increased hydrophobicity. The titanium and nitinol brushes caused more pronounced surface changes, while contributing to increased hydrophobicity through environmental carbon contamination during debridement. CLINICAL SIGNIFICANCE: Dental implant surface properties, including topography, morphology, wettability, and surface chemistry, play a critical role in bacterial adhesion and osseointegration. Selecting an optimal mechanical debridement instrument requires balancing the effective removal of biofilm with the impact on the implant surface properties.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. De Lauretis A, Santacroce M, Ellingsen JE, et al. Surface-specific outcomes of mechanical debridement with titanium, chitosan and nitinol brushes on titanium dental implant surfaces. J Dent. 2025. PMID: 40750080. doi:10.1016/j.jdent.2025.106010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。