文献速递口腔修复与种植

电解与化学联合去污对种植体表面的抗菌效果:体外研究

Antibacterial Effect of Combined Electrolytic and Chemical Decontamination Methods on Dental Implant Surfaces: In Vitro Study.
PubMed 文献 · Clin Oral Implants Res · 2025-08-07

该体外研究评估直流电与氯己定二葡萄糖酸盐(CHX)联合去污钛种植体表面的效果,使用经验证的口腔多菌种生物膜模型。联合处理组(-3V或-0.75V通电5分钟后0.12%CHX冲洗1分钟)较单用CHX及阴性对照显著降低活菌总数和残留细菌面积,去除超过95%生物膜。

要点

  • 联合处理较单用0.12%CHX显著降低种植体表面多菌种生物膜活菌数。
  • 联合处理去除超过95%生物膜,-3V与-0.75V间各参数无显著差异。
  • 电解清洁可到达种植体所有区域(螺纹、沟槽和穿黏膜机加工颈部)。

核心结论

  • 所提出的联合处理在降低种植体表面多菌种生物膜活力方面比单用0.12%CHX更有效。

研究设计与样本

  • 体外研究,使用经验证的口腔多菌种生物膜模型污染钛种植体表面。
  • 电化学池采用三电极系统浸于KI-AL电解液,生物膜覆盖的种植体为工作电极,铂网为对电极,Ag/AgCl为参比电极。
  • 直流电分别施加-3V和-0.75V电压5分钟,随后0.12%CHX冲洗1分钟。
  • 对照组为单用0.12%CHX和未处理的污染种植体(阴性对照)。
  • 采用PMA-qPCR和扫描电镜评估三个种植体区域(螺纹、沟槽和穿黏膜机加工颈部),并通过图像分析计算残留细菌面积。

主要发现

  • 联合处理组活菌总数:[-3V+CHX]为4.6 logCFU/mL,[-0.75V+CHX]为4.9 logCFU/mL。
  • 阴性对照组活菌总数为6.1 logCFU/mL,单用0.12%CHX组为6.3 logCFU/mL。
  • 联合处理组残留细菌面积显著减少,去除超过95%的生物膜,-3V效率略高。
  • 电解清洁可到达所有种植体区域,[-3V+CHX]与[-0.75V+CHX]在各项参数上无显著差异。

关键数值与推荐

  • 联合处理参数:直流电-3V或-0.75V通电5分钟,随后0.12%CHX冲洗1分钟。
  • 对照处理:单用0.12%CHX。
  • 疗效指标:活菌总数(logCFU/mL)和残留细菌面积。

临床怎么用

  • 联合电解与CHX去污可能比单用CHX更有效降低种植体表面多菌种生物膜活力。
  • 电解清洁可覆盖种植体螺纹、沟槽和穿黏膜颈部等所有区域。
  • -3V与-0.75V电压在体外效果无显著差异,临床电压选择需进一步研究。

局限性

  • 本研究为体外研究,结果不能直接外推至临床。
  • 未报告长期效果或种植体周围炎临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the combined effect of direct electrical current and chlorhexidine digluconate (CHX) for decontaminating titanium implant surfaces, using a validated in vitro oral multispecies biofilm model. MATERIAL AND METHODS: Contaminated implant surfaces were tested using an electrochemical cell consisting of a three-electrode system immersed in a KI-AL electrolyte, the biofilm-coated implant being the working electrode, a platinum mesh the counter electrode, and an Ag/AgCl electrode the reference. Direct electrical currents (DC) were applied at two voltage levels (-3 V and-0.75 V) for 5 min, followed by a 1-min rinse in 0.12% CHX. The results were compared to 0.12% CHX alone. Untreated contaminated implants served as negative controls. The antibiofilm effect was evaluated by quantitative polymerase chain reaction with propidium monoazide and by scanning electron microscopy in three different implant zones (threads, valleys and transmucosal machined neck). The area of residual bacteria was also calculated by image analysis. RESULTS: The combined treatment significantly reduced the viable total bacterial counts ([-3 V + CHX] = 4.6 and [-0.75 V + CHX] = 4.9 logarithm colony forming units-LogCFU/mL), compared to the negative control group (6.1 LogCFU/mL) and 0.12% CHX alone (6.3 LogCFU/mL). The area of residual bacteria was also significantly reduced, removing over 95% of the biofilm in combined treatment groups, with slightly higher efficiency at -3 V. Electrolytic cleaning was able to reach all implant zones and no significant differences were found between [-3 V + CHX] and [-0.75 V + CHX] for any parameter. CONCLUSION: The proposed combined treatments were more effective in reducing the vitality of multispecies biofilms on implant surfaces compared to CHX alone.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Odeh V, Virto L, Garcia-Quismondo E, et al. Antibacterial Effect of Combined Electrolytic and Chemical Decontamination Methods on Dental Implant Surfaces: In Vitro Study. Clin Oral Implants Res. 2025. PMID: 40772745. doi:10.1111/clr.70012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。