文献速递牙体牙髓病

根管封闭剂或氢氧化钙处理多菌种生物膜:抗菌活性与群落组成变化

Multispecies Biofilms Treated With Endodontic Sealers or Calcium Hydroxide: Antimicrobial Activity and Changes in Community Composition.
PubMed 文献 · Int Endod J · 2025-08-13

研究用牛牙本质圆柱感染龈下菌斑生物膜2周,比较AH Plus、BC Sealer和氢氧化钙处理7天后的抗菌效果与群落变化。氢氧化钙和BC Sealer显著降低细菌活性和DNA总量,AH Plus仅降低活性但显著改变群落组成,所有材料均未完全清除生物膜。

要点

  • 氢氧化钙和BC Sealer显著降低生物膜细菌活性和DNA总量
  • AH Plus降低细菌活性但不影响DNA浓度,且显著改变群落组成
  • 所有测试材料均不能完全清除多菌种生物膜

核心结论

  • 氢氧化钙和BC Sealer显著降低细菌活性和DNA拷贝总数,AH Plus仅降低活性而不影响DNA浓度。
  • AH Plus相比其他组显著改变整体生物膜群落组成。
  • 所有测试材料均未完全消除多菌种生物膜。

研究设计与样本

  • 设AH Plus、BC Sealer、氢氧化钙三处理组,丙烯二醇惰性载体和未处理污染样本为对照。
  • 感染根管空间与材料直接接触,厌氧孵育7天。
  • 采用厌氧培养(CFU)、qPCR和下一代测序评估效果。

主要发现

  • BC Sealer、AH Plus和氢氧化钙组的CFU、Shannon和Chao1指数与未处理对照和PG相比有显著差异(p < 0.003)。
  • 氢氧化钙和BC Sealer的qPCR值显著低于对照组和PG。
  • 生物膜组成(98.5%)主要由Peptostreptococcus、Streptococcus、Parvimonas、Fusobacterium、Veillonella、Mogibacterium、Lancefieldella、Eubacterium、Slackia和Prevotella构成。
  • 未处理对照与AH Plus之间的整体群落组成和β多样性有显著差异(ANOSIM R = 0.674,p < 0.001)。
  • Parvimonas、Streptococcus、Eubacterium和Lancefieldella不受任何测试材料影响。

关键数值与推荐

  • CFU、Shannon和Chao1指数在BC Sealer、AH Plus和氢氧化钙组与未处理对照及PG间差异显著(p < 0.003)。
  • 氢氧化钙和BC Sealer的qPCR值显著低于对照组和PG。
  • AH Plus与未处理对照的整体群落组成差异显著(ANOSIM R = 0.674,p < 0.001)。

临床怎么用

  • 氢氧化钙和BC Sealer可有效降低根管内多菌种生物膜的活性和DNA总量。
  • AH Plus虽不减少DNA总量,但可改变生物膜群落组成。
  • 临床需注意单一材料无法完全清除生物膜,应结合机械预备等措施。

局限性

  • 使用牛牙本质圆柱和龈下菌斑体外模型,未必完全模拟临床感染根管。
  • 接触时间为7天,短于某些临床封药周期。
  • 未评估材料对生物膜结构或宿主组织的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: To evaluate the antimicrobial activity and changes in community composition in biofilms treated with two root canal sealers or calcium hydroxide. MATERIAL AND METHODS: Forty-nine extracted bovine dentine cylinders were inoculated with subgingival dental plaque for 2 weeks in a CDC biofilm reactor. Three treatment groups were assigned: AH Plus, BC Sealer, and calcium hydroxide. Propylene glycol inert vehicle (PG) and untreated contaminated samples were used as controls. The infected root canal space was in direct contact with the materials for 7 days under anaerobic incubation. Anaerobic culture (colony forming units, CFU), quantification PCR (qPCR), and next generation sequencing were used to assess the effect of each material. Differences in the number of molecules (qPCR), CFU, and abundances of genera were evaluated using the Kruskal-Wallis test. The Shannon and Chao1 indices were used to measure alpha diversity. Differences in community composition were evaluated using non-parametric analysis of similarity (ANOSIM). RESULTS: The CFU, Shannon, and Chao1 indices revealed significant differences between BC Sealer, AH Plus, and calcium hydroxide groups versus the untreated control group and PG (p < 0.003). Calcium hydroxide and BC Sealer significantly reduced the qPCR values compared to the control group and PG. The biofilm composition (98.5%) was primarily composed of Peptostreptococcus, Streptococcus, Parvimonas, Fusobacterium, Veillonela, Mogibacterium, Lancefieldella, Eubacterium, Slackia, and Prevotella. Significant differences in overall community composition and beta diversity between untreated controls and AH Plus were observed (ANOSIM R = 0.674, p < 0.001). Parvimonas, Streptococcus, Eubacterium, and Lancefieldella were not affected by any of the materials tested. CONCLUSION: Calcium hydroxide and BC Sealer significantly reduced the viability and the total number of DNA copies. AH Plus sealer reduced the bacterial viability but did not affect the DNA concentration. AH Plus significantly alters overall biofilm community composition compared to other groups. None of the materials tested eliminated the multispecies biofilm completely.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Uttech SK, Ordinola-Zapata R, Noblett WC, et al. Multispecies Biofilms Treated With Endodontic Sealers or Calcium Hydroxide: Antimicrobial Activity and Changes in Community Composition. Int Endod J. 2025. PMID: 40808237. doi:10.1111/iej.70015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。