临床医生经验对动态计算机辅助种植精度影响的系统评价与Meta分析
该系统评价与Meta分析检索截至2025年4月19日的文献,纳入4项体内和10项体外研究,比较有或无dCAIS经验的医生使用dCAIS植入种植体的精度。结果显示,有dCAIS经验的医生在角度偏差上显著低于无经验者,但差异幅度可能无临床可感知性;种植手术经验本身未见显著影响。
要点
- 有dCAIS经验者角度偏差显著小于无经验者,但差异幅度可能无临床意义。
- 有无种植手术经验对dCAIS种植精度无统计学显著差异。
- 操作时间数据高度异质,无法得出确定性结论。
核心结论
- 医生经验的影响仅体现在有dCAIS经验与无dCAIS经验者之间的角度偏差上,差异幅度可能无临床可感知性。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Scopus、EMBASE和Cochrane Library至2025年4月19日,纳入4项体内和10项体外研究。
主要发现
- 体内研究合并分析显示角度偏差SMD=-0.35(-0.69,-0.01),p=0.04,有dCAIS经验者偏差更低。
- 体外研究合并分析显示角度偏差SMD=-0.39(-0.62,-0.17),p=0.0007,有dCAIS经验者偏差更低。
- 有无种植手术经验的医生之间,种植精度无统计学差异。
- 操作时间数据高度异质,无法得出确定性结论。
关键数值与推荐
- 有dCAIS经验者与无dCAIS经验者相比,角度偏差显著更低(体内SMD=-0.35,p=0.04;体外SMD=-0.39,p=0.0007)。
- 有无种植手术经验者之间,种植精度无统计学差异。
临床怎么用
- 使用dCAIS时,医生接受dCAIS专项培训可能有助于减小角度偏差。
- 种植手术经验本身不显著影响dCAIS种植精度,但需结合个体情况判断。
局限性
- 操作时间数据高度异质,无法得出确定性结论。
- 需要更多高质量、标准化的随机临床试验来合成有意义的证据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To synthesize evidence on the effect of clinicians' experience on the accuracy of implants placed using Dynamic Computer-Assisted Surgery systems (dCAIS). METHODS: PubMed, Scopus, EMBASE, and Cochrane Library were searched till April 19, 2025, for research reporting implant accuracy with dCAIS along with the influence of the operator's experience. Clinicians who had placed implants with dCAIS (dCAIS-Ex) were compared with those without any prior experience with dCAIS (dCAIS-IEx), irrespective of their experience with implant surgery; clinicians placing implants with dCAIS with or without prior experience in implant surgeries were also compared (IEx vs. I-InEx). The risk of bias was assessed with ROBINS-I for in vivo and QUIN tool for in vitro studies. Meta-analyses were performed to evaluate implant accuracy (coronal, apical, and angular deviations) and operating time. RESULTS: 4 in vivo and 10 in vitro studies were included. Pooled analysis of in vivo and in vitro studies showed significant differences in angular deviation [SMD = -0.35 (-0.69, -0.01), p = 0.04; SMD = -0.39 (-0.62, -0.17), p = 0.0007], where dCAIS-Ex clinicians showed lower deviations than dCAIS-IEx clinicians. No statistical difference was observed in implant accuracy between I-Ex versus I-IEx clinicians. Data was highly heterogeneous to report conclusive evidence on operating time with dCAIS between respective groups. CONCLUSIONS: The influence of clinicians' experience was significant only on angular deviation when implants were placed by dCAIS-Ex vs. dCAIS-InEx clinicians. However, the small magnitude of difference might not be clinically perceptible. More randomized clinical trials with high quality and standardized methodology are required to synthesize meaningful evidence.
引用
- Goyal L, Saroya KK, Sankar H, et al. Influence of Clinician's Experience on the Accuracy of Dental Implant Placement by Dynamic Computer-Assisted Surgery Systems: A Systematic Review and Meta-Analysis. Clin Oral Implants Res. 2025. PMID: 40717349. doi:10.1111/clr.70009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。