动态导航与机器人辅助牙种植体植入精度的体外模型对比研究

Evaluation of the accuracy of dynamic navigation versus robot-assisted dental implant placement in models with one missing tooth or multiple missing teeth with a free-end: an in vitro study.
PubMed 文献 · J Dent · 2025-07-08

该体外研究利用32个模型和86颗种植体,随机采用机器人辅助或动态导航系统植入,比较规划与实际位置偏差。机器人组中位角度偏差为1.15°,动态导航组为1.99°(P < 0.01)。两种方法均有高精度,但机器人辅助在多颗牙缺失的复杂病例中精度更优。

要点

  • 机器人辅助种植在整体模型上中位角度偏差显著低于动态导航(1.15° vs 1.99°,P < 0.01)。
  • 单颗牙缺失时两组仅在入点和根尖深度偏差有显著差异(P = 0.038和P = 0.032)。
  • 多颗连续缺失时机器人系统在角度、根尖及根尖水平偏差上均显著低于动态导航(P < 0.05)。

核心结论

  • 两种方法在体外种植植入中均达到高精度,但机器人辅助可能提供更高精度,尤其在多颗缺失牙的复杂病例中。

研究设计与样本

  • 体外研究,使用32个模型和86颗种植体,随机分配至机器人辅助组或动态导航系统组。
  • 通过叠加规划与实际种植体位置评估精度,主要结局为角度偏差,次要结局为入点和根尖水平的三维偏差。

主要发现

  • 整体模型中,机器人辅助组中位角度偏差为1.15°,动态导航组为1.99°(P < 0.01)。
  • 入点偏差分别为0.90 mm和0.92 mm,根尖偏差分别为1.00 mm和0.99 mm。
  • 单颗牙缺失模型中,两组在入点和根尖深度偏差上存在显著差异(P = 0.038和P = 0.032)。
  • 多颗牙缺失模型中,机器人辅助系统在角度、根尖及根尖水平偏差上均显著低于动态导航系统(P < 0.05)。

临床怎么用

  • 机器人辅助种植可能为多颗连续缺失牙等复杂病例提供更高植入精度。

局限性

  • 研究为体外模型实验,结论需临床进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess and compare the accuracy of robot-assisted and dynamic navigation systems for dental implant placement in models with either a single missing tooth or multiple consecutive missing teeth at the distal extension. METHODS: Thirty-two models and 86 implants were utilized. Implant placement was randomly assigned using either a robot-assisted or dynamic navigation system. The accuracy was evaluated by superimposing planned and actual implant positions. The primary study outcome was angular deviation, while secondary outcomes included three-dimensional deviations at the implant entry and apex levels. RESULTS: Across all models, the robot-assisted group demonstrated a median angular deviation of 1.15°, compared to 1.99° with the dynamic navigation system (P < 0.01). Entry and apex deviations were 0.90 mm vs. 0.92 mm and 1.00 mm vs. 0.99 mm, respectively. In single-tooth cases, significant differences between groups were observed in entry and apex depth deviations (P = 0.038 and P = 0.032, respectively). In models with multiple missing teeth, the robot-assisted system showed significantly lower angular, apex, and apex horizontal deviations than dynamic navigation system (P < 0.05). CONCLUSION: Both approaches yield a high degree of accuracy in vitro for implant placement. However, the robot-assisted approach may offer improved precision, particularly in complex cases involving multiple missing teeth. CLINICAL SIGNIFICANCE: The lower deviations in terms of accuracy demonstrated by the robot-assisted approach in the study would have potential benefits for the application of robots in relatively complex implant surgeries.