文献速递牙体牙髓病口腔颌面外科

根尖手术中术前CBCT与术中测量差异的影响因素

Factors Influencing Discrepancies between Presurgery Cone-beam Computed Tomography and Intraoperative Measurements in Apical Surgery.
PubMed 文献 · J Endod · 2025-07-23

本研究纳入90例患者(107颗牙)的101个手术位点,比较术前CBCT测量与根尖手术术中测量,评估CBCT检测颊侧皮质骨穿孔的准确性并分析差异相关因素。结果显示CBCT检测穿孔的灵敏度为90.6%、特异度为93.9%,且显著低估病变近远中径(P = .011)、高估剩余颊侧皮质骨板(BCP)领圈尺寸(P = .005);病变较大、下颌位置及根管充填与更大差异显著相关。

要点

  • CBCT检测颊侧皮质骨穿孔灵敏度90.6%、特异度93.9%。
  • CBCT显著低估病变近远中径(P = .011),高估BCP领圈(P = .005)。
  • 病变较大、下颌牙及根管充填者CBCT测量差异更大。

核心结论

  • CBCT在根尖手术规划中的测量准确性存在固有局限,差异受病变大小、牙位及根管状态影响,临床解读时应考虑这些因素以减少规划误差。

研究设计与样本

  • 纳入90例患者(107颗牙)计划行根尖手术,术前使用Planmeca ProMax 3D Classic设备(90 kV、10 mA、100 μm体素、5×5 cm视野)行CBCT,由三名校准检查者测量颊侧皮质骨穿孔的冠根向和近远中径及剩余BCP领圈冠根长度,并与术中测量比较,最终分析101个手术位点。

主要发现

  • CBCT检测皮质骨穿孔的灵敏度为90.6%、特异度为93.9%。
  • 配对统计检验显示CBCT显著低估病变近远中径(P = .011)。
  • CBCT显著高估BCP领圈尺寸(P = .005)。
  • 多因素广义线性模型分析表明,病变较大、下颌位置及存在根管充填与更大测量差异显著相关。

临床怎么用

  • 临床在根尖手术前解读CBCT时,应特别关注较大病变、下颌牙及有根管充填的病例,对其测量值保持审慎以减少规划误差。

局限性

  • 单中心研究,样本量有限(90例患者、101个位点),结果外推需谨慎。
  • CBCT参数固定为特定设备与视野,不同成像条件可能影响测量准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study evaluated the accuracy of cone-beam computed tomography (CBCT) in apical surgery planning by comparing preoperative CBCT measurements with intraoperative findings and identifying factors associated with discrepancies. METHODS: Ninety patients (107 teeth) scheduled for apical surgery underwent preoperative CBCT imaging using a Planmeca ProMax 3D Classic unit (90 kV, 10 mA, 100 μm voxel size, 5 × 5 cm field of view). Three calibrated examiners measured the apico-coronal and mesiodistal dimensions of buccal cortical bone perforations, as well as the apico-coronal length of the remaining buccal cortical plate (BCP) collar. CBCT measurements were compared to intraoperative measurements. Statistical analyses assessed associations between CBCT inaccuracies and variables including age, sex, lesion size, tooth type (anterior vs posterior), location (maxilla vs mandible), root canal status, and time interval between CBCT and surgery. RESULTS: A total of 101 surgical sites were analyzed. CBCT demonstrated a sensitivity of 90.6% and a specificity of 93.9% for detecting cortical plate perforations. Paired statistical tests revealed that CBCT significantly underestimated the mesiodistal dimension of lesions (P = .011) and overestimated the BCP collar dimension (P = .005). Multivariate generalized linear model analysis indicated that larger lesion size, mandibular location, and the presence of a root filling were significantly associated with greater discrepancies. CONCLUSIONS: CBCT demonstrates inherent limitations in measurement accuracy for apical surgery planning. Discrepancies are influenced by lesion size, tooth location, and root canal status. Clinicians should account for these factors when interpreting CBCT data to minimize preoperative planning errors.