加热对新型硅酸钙基根管封闭剂理化性能的影响
本研究评估加热至100°C持续1分钟对BC Sealer ion+、EndoSequence BC Sealer HiFlow和NeoSEALER EZFlo三种硅酸钙基根管封闭剂理化性能的影响。结果显示加热显著增加BC的初凝时间和NE的流动性,但未影响溶解度、钙释放和pH值。所有封闭剂的溶解度均不符合ADA标准。
要点
- 加热至100°C 1分钟可显著延长BC Sealer ion+的初凝时间并增加NeoSEALER EZFlo的流动性。
- 加热不影响三种封闭剂的溶解度、钙释放及pH值,但溶解度均未达ADA标准。
- 加热前后封闭剂的化学组成存在差异,但所有封闭剂在各时间点均呈碱性。
核心结论
- 加热改变了BC的初凝时间和NE的流动性,但未影响溶解度、钙释放或pH。
研究设计与样本
- 研究将BC Sealer ion+、EndoSequence BC Sealer HiFlow和NeoSEALER EZFlo分为加热组(100°C,1分钟)和未加热组,依据ISO和ANSI/ADA标准评估流动性、凝固时间和溶解度,采用电感耦合等离子体质谱法测定钙释放,并用能谱分析化学组成及测定不同时间点pH。
主要发现
- 加热显著增加BC的初凝时间和NE的流动性(P < .05)。
- 溶解度不符合ADA标准,且不受加热影响(P > .05)。
- 钙释放不受加热影响(P > .05),BC溶液中未检测到镁。
- 加热与未加热组的化学组成存在差异。
- 所有封闭剂在所有时间点均呈碱性,且不受加热影响。
关键数值与推荐
- 加热条件为100°C持续1分钟。
- 流动性、凝固时间和溶解度依据ISO和ANSI/ADA标准评估。
- pH在蒸馏水中于3、24、48和168小时测量。
- 数据采用ANOVA和Tukey检验,显著性水平P < .05。
临床怎么用
- 临床加热使用BC Sealer ion+时需注意初凝时间延长,使用NeoSEALER EZFlo时流动性增加可能影响操作。
- 加热不影响这三种封闭剂的溶解度和钙释放,但溶解度均不达ADA标准,需关注长期封闭性能。
- 加热后化学组成变化提示应评估其对材料性能的潜在影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The present study evaluated the effect of heating on the physicochemical properties of BC Sealer ion+ (BC), EndoSequence BC Sealer HiFlow (HF), and NeoSEALER EZFlo (NE). METHODS: Samples were divided into heated (H) and unheated (NH) groups, with the H-group subjected to 100°C for 1 minute. Flow, setting time, and solubility were evaluated according to ISO and ANSI/ADA standards. Calcium release was measured using inductively coupled plasma mass spectrometry, as well as the magnesium release by BC sealer. Chemical composition was analyzed using Energy-Dispersive X-ray Spectroscopy, and pH was measured after 3, 24, 48, and 168 hours in distilled water. Data were analyzed with ANOVA and Tukey tests (P < .05). RESULTS: Heating significantly increased the initial setting time of BC and the flow of NE (P < .05). Solubility did not meet ADA standards and was not affected by heating, as well as the calcium release (P > .05). No magnesium was detected in the BC solution. Chemical differences were observed between the H and NH groups. All sealers presented alkaline pH at all-time points, which was not influenced by heating. CONCLUSION: In conclusion, heating altered specific properties-initial setting time of BC and flow of NE-without affecting solubility, calcium release, or pH.
引用
- Scardini IL, Masiero AV, Dos Santos M, et al. Influence of Heating on the Physicochemical Properties of Novel Calcium Silicate-based Endodontic Sealers. J Endod. 2025. PMID: 40618889. doi:10.1016/j.joen.2025.06.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。