冲洗、钻头尺寸和转速对种植体窝洞制备界面热成像温度的影响:一项体外研究

Effect of Irrigation, Bur Size and Rotational Speed on Thermographic Heat at Implant Site Osteotomy Interface. An In Vitro Study.
PubMed 文献 · Clin Oral Implants Res · 2025-06-16

该体外研究在皮质牛骨上评估钻头直径、转速和冲洗对动态骨-钻界面温度的影响。结果显示,无冲洗、较大扩孔直径和较高转速是界面温度升高超过10°C的显著危险因素;有冲洗且200 rpm时各钻头直径组均未出现临界温升。

要点

  • 无冲洗时所有组温度均超过47°C,即使低转速也出现临界热应激。
  • 有冲洗且200 rpm时,两种钻头直径组均未出现临界温升。
  • 有冲洗时,直径差达1.4 mm的短缩方案在200 rpm下可安全实施。

核心结论

  • 无冲洗的种植窝洞制备会在骨-钻界面产生临界热应激,即使低钻速也是如此。
  • 在有冲洗且200 rpm时,可安全实施直径差达1.4 mm的短缩方案,从而在保持安全的同时缩短方案。

研究设计与样本

  • 体外研究,在厚3.5 mm的皮质牛骨上,将宽2.4 mm的预制备窝洞扩大至3.2或3.8 mm。
  • 使用双刃麻花钻,转速为200、600或1000 rpm,有或无生理盐水冲洗,并在动态骨-钻界面直接进行热成像测量。
  • 建立逻辑回归模型预测制备过程中达到≥47°C的可能性。

主要发现

  • 无冲洗、较大扩孔直径和较高转速是骨-钻界面温度升高超过10°C的显著危险因素(OR:冲洗177.53;扩孔步骤9.94;转速每增加400 rpm 4.94)。
  • 有冲洗时,200 rpm低转速下两种钻头直径组均未出现临界温升。
  • 无冲洗时,所有组温度均超过47°C。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to evaluate the impact of drill diameter, rotational speed, and irrigation on critical heat generation (≥ 47°C) at the dynamic bone-drill interface during dental implant osteotomy in pre-existing pilot bone cavities. MATERIAL AND METHODS: Bone samples were cut such that immediate and direct thermographic measurements at the dynamic bone-drill interface were possible. Osteotomy cavities of 2.4 mm width were expanded to either 3.2 or 3.8 mm in cortical bovine bone with a thickness of 3.5 mm, using two-bladed twist drills at rotational speeds of 200, 600, or 1000 rpm, with or without saline irrigation. A logistic regression model was developed to predict the likelihood of reaching temperatures ≥ 47°C during osteotomy based on these parameters. RESULTS: The absence of irrigation, major osteotomy diameter expansion, and higher rotational speeds were identified as significant risk factors for increasing the bone-drill interface temperature by more than 10°C (OR: irrigation 177.53; expansion step 9.94; speed by 400 rpm 4.94). No osteotomy performed at a low rotational speed (200 rpm) resulted in a critical temperature rise in either drill diameter group when irrigation was provided. However, temperatures exceeded 47°C across all groups when irrigation was absent. CONCLUSIONS: Dental implant osteotomy procedures without irrigation result in critical heat stress at the bone-drill interface, even at low drilling speeds. Shortened protocols with large drill diameter differences of up to 1.4 mm can be safely implemented when drilling at 200 rpm with irrigation. Osteotomy protocols can therefore be shortened while maintaining safety. TRIAL REGISTRATION: No clinical trial was included in the study.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Paeßens K, van Bebber L, Zipprich H, et al. Effect of Irrigation, Bur Size and Rotational Speed on Thermographic Heat at Implant Site Osteotomy Interface. An In Vitro Study. Clin Oral Implants Res. 2025. PMID: 40521678. doi:10.1111/clr.14462

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。