评估全引导静态计算机辅助种植手术后种植体支持覆盖义齿成功率的回顾性研究
本回顾性队列研究评估了全引导静态计算机辅助种植手术(sCAIS)放置四枚种植体支持杆式结构覆盖义齿的修复成功率、种植体存活率及植入精度;共纳入13例患者(10男3女,平均年龄69.3±4.84岁),植入60枚种植体并交付15副覆盖义齿(上颌11副、下颌4副),随访23.23±11.79个月,修复成功率100%、累积种植体存活率98.33%、种植体成功率93.33%,植入角度偏差3.19±1.73°、冠部全局偏差1.51±0.68 mm、根尖全局偏差中位数1.56 mm(范围3.77 mm)。
要点
- 四枚种植体支持杆式结构覆盖义齿修复成功率100%,累积种植体存活率98.33%。
- 种植体成功率93.33%,种植体周围炎发生率种植体水平3.33%、患者水平7.69%。
- sCAIS植入角度偏差3.19±1.73°,冠部全局偏差1.51±0.68 mm。
核心结论
- sCAIS放置四枚种植体支持的杆式结构覆盖义齿在两年随访期间表现出高修复成功率和临床可接受的生物学及生物力学并发症发生率。
研究设计与样本
- 回顾性队列研究,纳入13例患者(10男3女,平均年龄69.3±4.84岁),共植入60枚种植体并交付15副覆盖义齿(上颌11副、下颌4副),随访23.23±11.79个月。
主要发现
- 修复成功率为100%,累积种植体存活率为98.33%,种植体成功率为93.33%。
- 种植体周围炎发生率种植体水平为3.33%、患者水平为7.69%;种植体周围黏膜炎发生率种植体水平为28.33%、患者水平为46.15%。
- sCAIS植入角度偏差为3.19±1.73°,冠部全局偏差为1.51±0.68 mm,根尖全局偏差中位数为1.56 mm(范围3.77 mm)。
临床怎么用
- 作者认为,sCAIS放置四枚种植体支持的杆式结构覆盖义齿是无牙颌患者管理中可预测的治疗方式。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This retrospective cohort study aimed to determine the prosthetic success of overdentures supported by bar mesostructures on four dental implants, the survival rate of the implants placed using static Computer Assisted Implant Surgery (sCAIS), and the accuracy of implant placement. METHODS: Fully guided surgery was performed to place implants in the edentulous jaws of patients enrolled following virtual planning. Implant-supported overdentures were manufactured using a hybrid workflow. Patients were scheduled for clinical and radiographical evaluations and oral hygiene treatment at six-monthly intervals. The accuracy of implant placement was assessed by superimposing the postoperative desktop scans and the virtual plans. RESULTS: In total 60 implants were placed and 15 overdentures (11 maxillary and 4 mandibular) were delivered for 13 patients (10 male, 3 female; mean age: 69.3 ± 4.84 years) in this study. Patients were followed up for 23.23 ± 11.79 months. The prosthetic success, cumulative implant survival, and implant success rate were 100 %, 98.33 % and 93.33 % respectively. The incidence of periimplantitis was 3.33 % and 7.69, the incidence of periimplant mucositis was 28.33 % and 46.15 % on implant and patient level respectively. For the sCAIS procedures, the angular deviation was 3.19 ± 1.73 °, coronal global deviation was 1.51 ± 0.68 mm, and apical global deviation was 1.56 mm (median); range: 3.77 mm. CONCLUSION: Overdentures supported by bar mesostructures on four dental implants placed using sCAIS demonstrate a high rate of prosthetic success and a clinically acceptable incidence of biological and biomechanical complications during the two-year follow-up. CLINICAL SIGNIFICANCE: Delivering an overdenture supported by a bar mesostructure on four dental implants placed using sCAIS is a predictable treatment modality in the management of the edentulous patient.
引用
- Kivovics M, Orsós M, Birton NÉ, et al. A retrospective study evaluating the success of implant-supported overdentures following fully-guided static computer assisted implant surgery. J Dent. 2025. PMID: 40545229. doi:10.1016/j.jdent.2025.105924
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。