文献速递口腔修复与种植口腔颌面外科

人工智能工具在下颌切牙管CBCT分割中的比较:一项验证研究

Comparison of AI-Powered Tools for CBCT-Based Mandibular Incisive Canal Segmentation: A Validation Study.
PubMed 文献 · Clin Oral Implants Res · 2025-06-07

基于100例CBCT扫描开发增强AI模型用于下颌切牙管自动分割,并在另40例扫描中与人类专家及先前训练的AI模型比较;增强模型IoU、DSC、召回率、精确率、准确率分别为93%、93%、94%、93%、99%,RMSE为0.23 mm,分割耗时17.6秒,快于手动分割125倍。

要点

  • 增强AI模型下颌切牙管分割IoU 93%、DSC 93%、准确率99%、RMSE 0.23 mm。
  • 增强AI模型各指标显著高于先前训练的AI模型,IoU、DSC、召回率、准确率显著高于手动分割(p < 0.0001)。
  • 增强AI模型分割耗时17.6秒,比手动分割快125倍(p < 0.0001)。

核心结论

  • 增强AI模型可实现准确的下颌切牙管自动分割,且时间效率高,性能优于人类专家分割和先前训练的AI模型分割。

研究设计与样本

  • 基于100例CBCT扫描在Virtual Patient Creator平台开发增强AI模型,使用另40例CBCT扫描与人类专家及先前训练的AI模型对比验证。

主要发现

  • 增强AI模型的IoU为93%、DSC为93%、召回率为94%、精确率为93%、准确率为99%、RMSE为0.23 mm。
  • 增强AI模型所有指标均显著高于先前训练的AI模型,IoU、DSC、召回率和准确率显著高于手动分割(p < 0.0001)。
  • 增强AI模型分割耗时17.6秒,比手动分割快125倍(p < 0.0001)。

关键数值与推荐

  • 增强AI模型:IoU 93%、DSC 93%、召回率94%、精确率93%、准确率99%、RMSE 0.23 mm。
  • 增强AI模型在IoU、DSC、召回率、准确率上显著高于手动分割(p < 0.0001)。
  • 增强AI模型分割耗时17.6秒,手动分割的125倍(p < 0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Identification of the mandibular incisive canal (MIC) prior to anterior implant placement is often challenging. The present study aimed to validate an enhanced artificial intelligence (AI)-driven model dedicated to automated segmentation of MIC on cone beam computed tomography (CBCT) scans and to compare its accuracy and time efficiency with simultaneous segmentation of both mandibular canal (MC) and MIC by either human experts or a previously trained AI model. MATERIALS AND METHODS: An enhanced AI model was developed based on 100 CBCT scans using expert-optimized MIC segmentation within the Virtual Patient Creator platform. The performance of the enhanced AI model was tested against human experts and a previously trained AI model using another 40 CBCT scans. Performance metrics included intersection over union (IoU), dice similarity coefficient (DSC), recall, precision, accuracy, and root mean square error (RSME). Time efficiency was also evaluated. RESULTS: The enhanced AI model had IoU of 93%, DSC of 93%, recall of 94%, precision of 93%, accuracy of 99%, and RMSE of 0.23 mm. These values were significantly higher than those of the previously trained AI model for all metrics, and for manual segmentation for IoU, DSC, recall, and accuracy (p < 0.0001). The enhanced AI model demonstrated significant time efficiency, completing segmentation in 17.6 s (125 times faster than manual segmentation) (p < 0.0001). CONCLUSION: The enhanced AI model proved to allow a unique and accurate automated MIC segmentation with high accuracy and time efficiency. Besides, its performance was superior to human expert segmentation and a previously trained AI model segmentation.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. da Andrade-Bortoletto MFS, Jindanil T, Fontenele RC, et al. Comparison of AI-Powered Tools for CBCT-Based Mandibular Incisive Canal Segmentation: A Validation Study. Clin Oral Implants Res. 2025. PMID: 40481776. doi:10.1111/clr.14455

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。