基于3D分割策略的智能虚拟牙种植体放置
本研究基于nnU-Net开发分割模块,从锥形束CT(CBCT)无牙区生成虚拟种植体,并用近似模块进行数学优化,实现下颌第一磨牙缺失的智能虚拟种植体放置。共收集4个中心190例CBCT用于模型开发与测试,内部和外部测试集表面Dice系数分别为0.903和0.884,种植体平台、根尖和角度的平均偏差在内部测试集为0.850±0.554 mm、1.442±0.539 mm和4.927±3.804°,外部测试集为0.822±0.353 mm、1.467±0.560 mm和5.517±2.850°。
要点
- 基于nnU-Net的分割模块可从CBCT无牙区生成虚拟种植体。
- 内部和外部测试集表面Dice系数分别为0.903和0.884。
- 种植体平台、根尖和角度平均偏差内部测试集为0.850±0.554 mm、1.442±0.539 mm和4.927±3.804°。
核心结论
- 基于3D分割的人工智能工具在预测虚拟种植体尺寸和位置方面表现良好,在种植规划中显示出显著临床应用潜力。
研究设计与样本
- 研究聚焦下颌第一磨牙缺失,开发基于nnU-Net的分割模块从CBCT无牙区生成虚拟种植体,并采用近似模块进行数学优化。
- 共收集来自4个中心的190例CBCT扫描用于模型开发与测试。
主要发现
- 内部测试集表面Dice系数为0.903,外部测试集为0.884。
- 与真实值相比,内部测试集种植体平台、根尖和角度的平均偏差分别为0.850±0.554 mm、1.442±0.539 mm和4.927±3.804°。
- 外部测试集种植体平台、根尖和角度的平均偏差分别为0.822±0.353 mm、1.467±0.560 mm和5.517±2.850°。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Virtual dental implant placement in cone-beam computed tomography (CBCT) is a prerequisite for digital implant surgery, carrying clinical significance. However, manual placement is a complex process that should meet clinical essential requirements of restoration orientation, bone adaptation, and anatomical safety. This complexity presents challenges in balancing multiple considerations comprehensively and automating the entire workflow efficiently. This study aims to achieve intelligent virtual dental implant placement through a 3-dimensional (3D) segmentation strategy. Focusing on the missing mandibular first molars, we developed a segmentation module based on nnU-Net to generate the virtual implant from the edentulous region of CBCT and employed an approximation module for mathematical optimization. The generated virtual implant was integrated with the original CBCT to meet clinical requirements. A total of 190 CBCT scans from 4 centers were collected for model development and testing. This tool segmented the virtual implant with a surface Dice coefficient (sDice) of 0.903 and 0.884 on internal and external testing sets. Compared to the ground truth, the average deviations of the implant platform, implant apex, and angle were 0.850 ± 0.554 mm, 1.442 ± 0.539 mm, and 4.927 ± 3.804° on the internal testing set and 0.822 ± 0.353 mm, 1.467 ± 0.560 mm, and 5.517 ± 2.850° on the external testing set, respectively. The 3D segmentation-based artificial intelligence tool demonstrated good performance in predicting both the dimension and position of the virtual implants, showing significant clinical application potential in implant planning.
引用
- Cai G, Wen B, Gong Z, et al. Intelligent Virtual Dental Implant Placement via 3D Segmentation Strategy. J Dent Res. 2025. PMID: 40551483. doi:10.1177/00220345251332511
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。