文献速递口腔修复与种植

部分牙列缺损患者中数字与常规种植印模的准确性:系统综述与荟萃分析

Accuracy of digital versus conventional implant impressions in partially dentate patients: A systematic review and meta-analysis.
PubMed 文献 · J Dent · 2025-06-17

该系统综述与荟萃分析比较了部分牙列缺损种植患者中数字印模与常规印模的准确性,纳入7项临床研究共151例患者。结果显示数字印模在偏差上显著低于常规印模,但角度位移无显著差异,研究间存在较大异质性(I²=80-97%)。作者认为数字印模可作为短跨度种植修复的临床可接受替代方案,但长跨度或角度种植体需谨慎。

要点

  • 数字印模偏差显著低于常规印模,但角度位移无显著差异。
  • 研究间异质性较大(I²=80-97%),限制合并结果的确定性。
  • 数字印模可用于短跨度种植修复,长跨度或角度种植体需谨慎。

核心结论

  • 数字印模偏差显著低于常规印模,在某些临床情况下空间准确性更优。
  • 角度位移无显著差异。
  • 研究间存在较大异质性(I²=80-97%),限制合并结果的确定性。
  • 数字印模是部分牙列缺损患者短跨度种植修复的临床可接受替代方案,但长跨度或角度种植体需谨慎。
  • 需要进一步高质量、标准化方案的临床试验来支持更广泛的临床 adoption。

研究设计与样本

  • 系统综述与荟萃分析,检索5个数据库(PubMed、EMBASE、Web of Science、CINAHL、Cochrane Library),检索时间为2025年3月。
  • 遵循PRISMA 2020指南,前瞻性注册于PROSPERO(CRD420251006999)和INPLASY(INPLASY202530032)。
  • 纳入7项临床研究,共151例部分牙列缺损患者;仅3项研究贡献角度位移荟萃分析数据,4项研究贡献偏差分析数据。
  • 纳入研究包括随机对照试验和非随机临床研究,比较口内扫描仪(IOS)数字印模与使用聚乙烯基硅氧烷或聚醚材料的常规印模。

主要发现

  • 数字印模偏差显著低于常规印模。
  • 角度位移无显著差异。
  • 研究间异质性I²=80-97%。

临床怎么用

  • 数字印模是部分牙列缺损患者中常规方法的临床可接受替代方案。
  • 在长跨度修复或角度种植体情况下,临床医生应谨慎,直至有进一步高质量、标准化方案和长期数据的研究。

局限性

  • 研究间存在较大异质性(I²=80-97%),限制合并结果的确定性。
  • 需要进一步高质量、标准化方案的临床试验来支持更广泛的临床 adoption。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the accuracy of digital and conventional impression techniques in partially dentate patients undergoing implant-supported prosthodontic treatment. The primary focus was three-dimensional accuracy, including angular and linear deviations, inter-implant distances, and scan-body misfit. DATA: Data were extracted from seven clinical studies involving 151 partially dentate patients. Only three studies contributed data to the angular displacement meta-analysis, and four studies to the deviation analysis. The studies included randomised controlled trials and non-randomised clinical investigations comparing intraoral scanner (IOS)-based digital impressions with conventional impressions using polyvinyl siloxane or polyether materials. SOURCES: A systematic search was conducted in March 2025 across five databases: PubMed, EMBASE, Web of Science, CINAHL, and the Cochrane Library. PRISMA 2020 guidelines conducted the review and were prospectively registered with PROSPERO (CRD420251006999) and the International Platform of Registered Systematic Review and Meta-analysis Protocols (INPLASY202530032). STUDY SELECTION: Eligible studies were those that clinically assessed impression accuracy in partially dentate implant patients using either digital or conventional methods. Studies were included if they reported quantitative measures of impression accuracy. In vitro studies, non-implant restorative comparisons, and fully edentulous patient cohorts were excluded. CONCLUSIONS: Digital impressions demonstrated significantly lower deviation than conventional impressions, indicating superior spatial accuracy in certain clinical settings. However, no significant difference was observed in angular displacement. Considerable heterogeneity (I² = 80-97 %) across studies limits the certainty of pooled outcomes. Digital impressions are a clinically acceptable alternative for short-span implant restorations in partially dentate patients, though caution is warranted in cases involving long-span or angulated implants. Further high-quality clinical trials with standardised protocols are needed to support broader clinical adoption. CLINICAL IMPORTANCE: Digital impressions are a clinically acceptable alternative to conventional methods in partially dentate patients. Nevertheless, clinicians should exercise caution in long-span restorations or angulated implants until further high-quality studies with standardised protocols and long-term data are available.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Park JS, Alshehri YFA, Kruger E, et al. Accuracy of digital versus conventional implant impressions in partially dentate patients: A systematic review and meta-analysis. J Dent. 2025. PMID: 40553823. doi:10.1016/j.jdent.2025.105918

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。