深缘提升与CAD/CAM部分二硅酸锂修复体后牙周参数的两年评估——一项前瞻性对照临床试验
这项前瞻性临床试验在深缘提升(DME)修复体放置2年后评估牙周参数,并与基线值及同一牙齿对侧龈上/龈缘边缘(对照)比较。68例患者77个修复体纳入,2年时51例患者57个修复体复评。2年后DME位点探诊出血(BOP)较基线显著增加,探诊深度(PD)DME显著高于对照,但两组2年内保持稳定。结论:邻面DME与2年复查时牙龈炎症增加相关。
要点
- 2年后DME位点BOP较基线显著增加(padj.=0.010),对照位点无显著变化(padj.=0.517)。
- 2年后PD在DME与对照间有显著差异(padj.=0.015),但两组2年内均保持稳定。
- 菌斑指数(PI)两组均显著增加(padj.<0.001),但两侧间无显著差异(padj.=0.341)。
核心结论
- 邻面DME与2年复查时牙龈炎症增加相关,但牙周状况在放置后第一年后保持稳定。
研究设计与样本
- 前瞻性对照临床试验,纳入68例患者77个修复体,2年时复评51例患者57个修复体。
- (前)磨牙单侧龈下邻面缺损采用复合树脂DME和CAD/CAM制造的二硅酸锂部分修复体修复。
- 牙周参数(探诊出血BOP、探诊深度PD、菌斑指数PI)在陶瓷插入后(基线)和2年随访时记录,DME与对照间比较采用Fisher精确检验和Wilcoxon符号秩检验,p<0.05。
主要发现
- 基线时牙周参数无显著差异。
- 2年后DME位点BOP较基线显著增加(padj.=0.010),对照位点无显著变化(padj.=0.517);但DME与对照间BOP无显著差异(padj.=0.110)。
- 2年后PD在DME显著高于对照(padj.=0.015),但两组2年内均保持稳定(DME:padj.=0.171,对照:padj.=0.517)。
- PI两组均显著增加(padj.<0.001),但两侧间无显著差异(padj.=0.341)。
- 2个修复体被替换(陶瓷折裂、继发龋),1颗牙发生根尖周炎。
临床怎么用
- DME是修复深邻面缺损的有前景方法,但邻面DME与牙龈炎症增加相关。
- 牙周状况在放置后第一年后保持稳定。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This prospective clinical trial evaluated periodontal parameters at proximal deep-margin-elevation (DME) restoration margins 2 years after placement and compared them with baseline values and with supragingival/equigingival margins (control) on the opposite proximal surface of the same tooth. METHODS: One-sided subgingival proximal defects in (pre-)molars were restored using composite DME and CAD/CAM-manufactured lithium disilicate partial restorations. Periodontal parameters (bleeding on probing (BOP), probing depths (PD), plaque index (PI)) were recorded after ceramic insertion (baseline) and at 2-year follow-up, and compared between DME and control (Fisher's exact test and Wilcoxon signed rank test, p < 0.05). RESULTS: Sixty-eight patients with 77 restorations were included; 51 patients with 57 restorations were re-evaluated at 2 years. Two restorations were replaced (ceramic fracture, secondary caries), and one tooth developed apical periodontitis. Periodontal parameters were not significantly different at baseline. After 2 years, BOP increased significantly at the DME (padj. = 0.010), but not at controls (padj. = 0.517); but BOP was not significantly different between DME and control (padj. = 0.110). PD was significantly higher in DME vs. control (padj. = 0.015), but remained stable in both groups over the 2-year period (DME: padj. = 0.171, control: padj. = 0.517). PI increased significantly in both groups (padj. < 0.001), but did not differ between both sides (padj. = 0.341). CONCLUSION: Proximal DME was associated with increased gingival inflammation at 2-year recall compared to baseline. CLINICAL SIGNIFICANCE: DME is a promising approach for restoring teeth with deep proximal defects, but proximal DME is associated with increased gingival inflammation. The periodontal situation remains stable after the first year of placement.
引用
- Hausdörfer T, Kanzow P, Rödig T, et al. Two-year evaluation of periodontal parameters following deep-margin-elevation and CAD/CAM partial lithium disilicate restorations - a prospective controlled clinical trial. J Dent. 2025. PMID: 40532278. doi:10.1016/j.jdent.2025.105901
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。