5种预混硅酸钙基封闭剂在新型离体模型中牙本质小管内抗菌效能与pH及钙离子释放的相关性
本研究采用新型离体模型,将64个感染粪肠球菌的牙本质块分别用5种预混硅酸钙基封闭剂及对照组充填,评估1周和4周时牙本质小管内抗菌效能,并检测封闭剂浸提液的pH和钙离子浓度。结果显示各封闭剂组抗菌效能无显著差异,所有组4周时抗菌效能显著高于1周;HiFlow、BC Sealer和BioRoot Flow的pH和钙离子浓度高于BIOC+和NeoSEALER Flo;pH与钙离子浓度呈强正相关。
要点
- 5种预混硅酸钙基封闭剂在牙本质小管内抗菌效能相似,尽管pH和钙离子释放存在差异。
- 所有封闭剂组4周时抗菌效能显著高于1周(P < .05)。
- HiFlow、BC Sealer和BioRoot Flow的pH和钙离子浓度高于BIOC+和NeoSEALER Flo(P < .05)。
核心结论
- 受试的预混硅酸钙基封闭剂在牙本质小管内表现出相似的抗菌效能,尽管pH和钙离子释放存在差异。
研究设计与样本
- 选取40颗单根管人前磨牙,制备64个牙本质块,灭菌后接种粪肠球菌3周,其中4个感染块用于扫描电镜分析,60个感染块嵌入3D打印牙齿并分为6组:对照组、BIO-C SEALER ION+(BIOC+)、EndoSequence BC Sealer HiFlow、EndoSequence BC Sealer、NeoSEALER Flo和BioRoot Flow,采用单锥技术充填。
主要发现
- 充填后1周和4周,各封闭剂组间抗菌效能无显著差异,所有组4周时抗菌效能显著高于1周(P < .05)。
- 第1天、1周和4周时,所有封闭剂pH值均高于11,各时间点组间差异显著(P < .05)。
- 各时间点封闭剂间钙离子浓度差异显著(P < .05)。
- HiFlow、BC Sealer和BioRoot Flow在所有时间点的pH值和钙离子浓度均高于BIOC+和NeoSEALER Flo(P < .05)。
- 所有时间点pH值与钙离子浓度呈强正相关(P < .05)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: To evaluate the antibacterial efficacy of 5 premixed calcium silicate-based sealers in infected dentinal tubules using a novel ex vivo model, and to investigate correlations among antibacterial efficacy, pH, and calcium ion release. METHODS: Forty human premolars with a single canal were selected and stored in 0.01% sodium hypochlorite solution at 4 °C. The teeth were sectioned to obtain 64 dentin blocks, which were sterilized and inoculated with Enterococcus faecalis for 3 weeks. Four infected blocks were analyzed using scanning electron microscopy. Sixty infected blocks were fitted into 3D-printed teeth and assigned to 6 groups based on the sealer used: Control, BIO-C SEALER ION+ (BIOC+), EndoSequence BC Sealer HiFlow, EndoSequence BC Sealer, NeoSEALER Flo, and BioRoot Flow. Specimens were subsequently obturated using the single-cone technique. Antibacterial efficacy was evaluated at 1 and 4 weeks using viability staining and confocal laser scanning microscopy. Leachates from sealer discs were collected to analyze pH and calcium ion at day 1, 1 week, and 4 weeks. Statistical analysis was performed using one-way ANOVA, unpaired t-test, and Spearman's correlation (α = 0.05). RESULTS: At 1 and 4 weeks after obturation, no significant differences in antibacterial efficacy were observed among the sealer groups; all groups exhibited significantly higher antibacterial efficacy at 4 weeks compared to 1 week (P < .05). At day 1, 1 week, and 4 weeks, all sealers exhibited pH values above 11, with significant differences observed among them at each time point (P < .05). Calcium ion concentrations differed significantly among sealers at all-time points (P < .05). HiFlow, BC Sealer, and BioRoot Flow showed higher pH values and calcium ion concentrations than BIOC+ and NeoSEALER Flo at all-time points (P < .05). A strong positive correlation was found between pH values and calcium ion concentrations at all-time points (P < .05). CONCLUSIONS: The tested premixed calcium silicate-based sealers demonstrated similar antibacterial efficacy in dentinal tubules, despite variations in pH and calcium ion release.