一种新型口内摄影测量技术用于全牙弓种植体印模的精度:一项体外研究

Accuracy of a Novel Intraoral Photogrammetry Technique for Complete-Arch Implant Impressions: An In Vitro Study.
PubMed 文献 · Clin Oral Implants Res · 2025-05-07

本研究在体外比较了四种数字化技术制取全牙弓种植体印模的精度:口外摄影测量(EPG)、使用原始扫描杆的口内扫描(IOS)、使用预制辅助装置的口内扫描(IOSA)和口内摄影测量(IPG)。每种技术获取10组扫描数据,测量相对于参考扫描的均方根误差、基台类似物间的距离和角度偏差以及扫描时间。IPG在均方根误差真实度、距离偏差上表现最佳,EPG在精密度上最佳,角度偏差无显著差异,IOSA扫描时间最长;结论认为IPG在体外达到与EPG相当的精度,但需进一步临床研究验证。

要点

  • IPG的均方根误差真实度为26.37±1.02 μm,优于EPG、IOS和IOSA(均p<0.050)。
  • EPG的均方根误差精密度为2.30±1.31 μm,优于IPG、IOS和IOSA(均p<0.001)。
  • 各组角度偏差无显著差异(p=0.313),IOSA扫描时间最长(125.00±18.74秒,均p<0.001)。

核心结论

  • IPG在全牙弓种植体数字化印模的体外研究中达到了与EPG相当的精度,提供高效简洁的工作流程,可作为有价值的替代方法,但需进一步临床研究验证其效能。

研究设计与样本

  • 体外研究,使用一个带有六个平行基台类似物的无牙上颌主模型,以实验室扫描仪扫描作为参考扫描。
  • 每种技术获取10组扫描数据,比较EPG、IOS、IOSA和IPG四种技术。

主要发现

  • 均方根误差真实度:IPG为26.37±1.02 μm,EPG为31.72±0.59 μm,IOS为39.93±7.98 μm,IOSA为50.60±12.46 μm,IPG显著最佳(均p<0.050)。
  • 均方根误差精密度:EPG为2.30±1.31 μm,IPG为4.12±0.87 μm,IOS为33.38±13.95 μm,IOSA为28.35±11.48 μm,EPG显著最佳(均p<0.001)。
  • 距离偏差:IPG为28.59±24.75 μm,EPG为55.55±37.82 μm,IOS为62.97±50.60 μm,IOSA为93.37±72.15 μm,IPG显著最佳(均p<0.050)。
  • 角度偏差无显著差异(p=0.313)。
  • 扫描时间:IPG为50.30±6.77秒,EPG为57.40±5.19秒,IOS为91.10±20.31秒,IOSA为125.00±18.74秒,IOSA显著最长(均p<0.001)。

临床怎么用

  • 作者认为IPG提供高效简洁的工作流程,可作为有价值的替代方法,但需进一步临床研究验证其效能。

局限性

  • 原文指出需进一步临床研究来验证IPG的效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the accuracy of complete-arch implant impressions using four digital techniques: extraoral photogrammetry (EPG), intraoral scanning with original scan body (IOS), intraoral scanning with prefabricated aids (IOSA), and intraoral photogrammetry (IPG). MATERIALS AND METHODS: One edentulous maxillary master model with six parallel abutment analogs was scanned by a laboratory scanner as the reference scan. EPG, IOS, IOSA, and IPG were used to scan the master model with respective scan bodies as test scans. Ten scanning data were gained for each technique. Trueness and precision of root mean square (RMS) errors were measured between the test and reference scans. Deviations in distance and angle relative to the reference scan between all pairs of abutment analogs were measured. Scanning time was recorded. RESULTS: IPG showed significantly best trueness in RMS errors (IPG, 26.37 ± 1.02 μm; EPG, 31.72 ± 0.59 μm; IOS, 39.93 ± 7.98 μm; IOSA, 50.60 ± 12.46 μm), (all p < 0.050). EPG showed significantly best precision in RMS errors (EPG, 2.30 ± 1.31 μm; IPG, 4.12 ± 0.87 μm; IOS, 33.38 ± 13.95 μm; IOSA, 28.35 ± 11.48 μm), (all p < 0.001). IPG demonstrated significantly best performance in distance deviation (IPG, 28.59 ± 24.75 μm; EPG, 55.55 ± 37.82 μm; IOS, 62.97 ± 50.60 μm; IOSA, 93.37 ± 72.15 μm), (all p < 0.050). No significant differences were found regarding angle deviation (p = 0.313). IOSA showed the longest scanning duration (IPG: 50.30 ± 6.77 s; EPG: 57.40 ± 5.19 s; IOS: 91.10 ± 20.31 s; IOSA: 125.00 ± 18.74 s), (all p < 0.001). CONCLUSIONS: IPG achieved comparable accuracy with EPG in complete-arch implant digital impressions in vitro. IPG offers an efficient and straightforward workflow, making it a valuable alternative method; however, further clinical studies are needed to validate its efficacy.