文献速递牙体牙髓病

用于再生牙髓封盖材料细胞生物相容性研究的体外管模型

An In Vitro Tube Model for Cell Biocompatibility Study of Capping Materials for Regenerative Endodontics.
PubMed 文献 · J Endod · 2025-05-09

本研究利用锥形塑料管模拟根管空间,内充荧光标记牙髓细胞与纤维蛋白凝胶混合物,大端以MTA、Biodentine、羟基磷灰石-磷酸三钙(HA-TCP)、复合树脂或玻璃离子封闭,观察细胞形态及管内pH变化。结果显示新鲜MTA和Biodentine对细胞有不良影响,HA-TCP与细胞相容性最高,但用HA-TCP隔离细胞与新鲜MTA或Biodentine并未减轻后两者的负面影响,管内pH升高可能解释所观察到的毒性。

要点

  • 新鲜MTA和Biodentine对管内牙髓细胞有不良影响,仅根尖处见少量正常生长细胞。
  • HA-TCP混合纤维蛋白凝胶与细胞相容性最高。
  • 用HA-TCP隔离细胞与新鲜MTA或Biodentine未减轻两种硅酸钙材料的负面影响。

核心结论

  • 以HA-TCP混合纤维蛋白凝胶作为封盖材料对细胞似乎高度相容,而新鲜MTA和Biodentine则不相容。

研究设计与样本

  • 体外研究:使用长14 mm、根尖开口直径2 mm的锥形塑料管模拟根管空间,内充荧光标记牙髓细胞与纤维蛋白凝胶混合物,大端分别以MTA、Biodentine、HA-TCP、复合树脂和玻璃离子封闭,置于培养板孔中体外孵育不同时间,显微镜下观察细胞形态变化,并监测管内pH随时间的变化。

主要发现

  • 新鲜MTA和Biodentine均引起管内细胞不良应答,仅根尖端观察到少量正常生长细胞。
  • 复合树脂或玻璃离子对细胞似乎耐受性较好。
  • HA-TCP混合纤维蛋白凝胶表现出最高的细胞相容性。
  • 使用HA-TCP将细胞与新鲜MTA或Biodentine隔开并未减轻这两种硅酸钙水门汀的负面影响。
  • 管内pH升高可能解释所观察到的毒性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Cell-based pulp regeneration utilizes capping materials underneath a final restoration to seal the tooth after delivering cells into the canal system. Studying the immediate biocompatibility of materials with injected cells has been challenging. This study aimed to utilize a tube model to observe cell response directly and conveniently to the capping materials in a cell culture in vitro system. METHODS: A tapered plastic tube (14 mm in length, 2 mm diameter of the apex opening) to simulate root canal space was filled with fluorescence-labeled dental pulp cells mixed in fibrin gel and the larger end sealed with various capping materials including Mineral Trioxide Aggregate (MTA), Biodentine, hydroxyapatite-tricalcium phosphate (HA-TCP), composite, and glass ionomer. The tube was placed in wells of culture plates and incubated for various times in vitro and observed under the microscope for cell morphological changes. pH changes within the tube were monitored over time. RESULTS: Both fresh MTA and Biodentine caused adverse response to the cells in the tube. Only a few normally growing cells were observed at the apical end. Composite or glass ionomer appeared better tolerated by cells. HA-TCP mixed in fibrin gel demonstrated the highest compatibility with cells; however, using HA-TCP to separate cells from fresh MTA or Biodentine did not reduce the negative effect of these 2 calcium silicate cements. The pH increased within the tube may explain the observed toxicity. CONCLUSIONS: Using HA-TCP mixed in fibrin gel as a capping material appears highly biocompatible to cells while fresh MTA and Biodentine are not.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Pilbauerova N, Dasi D, de Souza Araujo IJ, et al. An In Vitro Tube Model for Cell Biocompatibility Study of Capping Materials for Regenerative Endodontics. J Endod. 2025. PMID: 40348362. doi:10.1016/j.joen.2025.04.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。