评估两段式氧化锆与钛种植体上螺丝固位混合基台冠3年存留率和技术并发症的随机对照试验
60名受试者随机均分接受氧化锆或钛种植体,评估螺丝固位二硅酸锂冠(SIC)在聚醚酮酮(PEKK)基台与钛基台联合种植体上的3年累计存留和技术并发症。氧化锆组累计存留率较钛组(100%)低10.7%,非劣效性未获证实;技术并发症率低且组间无统计学显著差异。结论认为PEKK基台混合基台SIC可用于两段式氧化锆种植体,但需考虑氧化锆种植体较低的骨结合率。
要点
- 氧化锆组累计存留率较钛组(100%)低10.7%,非劣效性未获证实。
- 技术并发症率低,两组间无统计学显著差异。
- 12个月时PES较基线显著改善,组间无显著差异。
核心结论
- 两段式氧化锆种植体上PEKK基台混合基台SIC可作为钛种植体上钛基台混合基台SIC的替代方案,但须考虑氧化锆种植体较低的骨结合率。
研究设计与样本
- 随机对照试验,60名受试者随机均分接受氧化锆或钛种植体,评估SIC存留和技术并发症至36个月。
- SIC累计存留采用非劣效性设计,假定钛组与氧化锆组差异不超过10%。
主要发现
- 氧化锆组发生3例早期种植体失败,均成功修复。
- 基线后氧化锆组3枚种植体因骨结合不足丢失,相应SIC归类为失败,尽管无SIC本身失败。
- 氧化锆组累计存留率较钛组(100%)低10.7%,非劣效性未获证实。
- 技术并发症率低,组间无统计学显著差异。
- PES较基线显著改善,12个月时组间无显著差异。
关键数值与推荐
- 技术并发症依据改良USPHS标准和粉红美学评分(PES)评估。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study compares the cumulative survival and technical complications of screw-retained implant-supported lithium disilicate crowns (SICs) on polyether ketone ketone (PEKK) base abutments and zirconia implants with those of titanium base abutments and titanium implants. MATERIALS AND METHODS: Sixty participants were randomly and evenly assigned to receive zirconia or titanium implants. Survival and technical complications were assessed at 6 weeks after crown placement (baseline) up to 36 months. The cumulative survival of the SICs was analysed as a non-inferiority design, assuming that the difference between the titanium group and the zirconia group is not more than 10%. Technical complications were assessed based on modified USPHS criteria and Pink Aesthetic Score (PES). RESULTS: In the zirconia group, three early implant failures occurred; all of them were successfully revised. After baseline, three implants in the zirconia group were lost due to insufficient osseointegration, and therefore the SICs have to be categorised as failures even though none of the SICs failed. The non-inferiority of the zirconia group could not be confirmed, as the cumulative survival was 10.7% lower compared to the titanium group (100%). The technical complication rate was low, with no statistically significant difference between the groups. The PESs improved significantly compared to baseline, with no significant difference between the groups at 12 months. CONCLUSION: Hybrid abutment SICs with PEKK base abutments on two-piece zirconia implants could be an alternative to hybrid abutments SICs with titanium base on titanium implants. However, the lower osseointegration rate of the zirconia implants has to be considered. TRIAL REGISTRATION: This study was registered in the German Clinical Trial Register (Deutsches Register Klinischer Studien) (number: DRKS00014866).
引用
- Sterzenbach G, Richter K, Alpen K, et al. A Randomised Controlled Trial Evaluating 3-Year Survival Rates and Technical Complications of Screw-Retained Hybrid Abutment Crowns on Two-Piece Zirconia and Titanium Implants. Clin Oral Implants Res. 2025. PMID: 40297919. doi:10.1111/clr.14443
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。