数字化印模方法捕捉种植体周围穿龈轮廓准确性的系统综述
本系统综述纳入24项前瞻性介入或观察性临床研究,评估5种数字化技术捕捉单颗种植修复体周围穿龈轮廓的准确性。直接扫描技术显示明显的软组织塌陷;间接扫描与常规方法可获得相似结果。作者认为间接穿龈轮廓扫描是最有前景的方法,但需随机临床试验的定量分析确认。
要点
- 直接扫描技术显示明显的软组织塌陷。
- 间接扫描与常规方法可获得相似结果。
- 间接穿龈轮廓扫描似乎是最有前景的方法。
核心结论
- 间接穿龈轮廓扫描似乎是最有前景的捕捉种植体周围穿龈轮廓的方法。
- 该发现的确认需通过随机临床试验进行定量分析。
研究设计与样本
- 系统综述,纳入前瞻性介入或观察性临床研究,聚焦单颗种植修复体周围穿龈轮廓的数字化映射。
- 排除系统综述、体外和动物研究以及未强调穿龈轮廓捕捉的研究。
- 2024年8月7日检索四个数据库(MEDLINE、CENTRAL、Embase、Web of Science),基于预先注册方案(PROSPERO注册号:CRD42023459484)。
- 采用RoB 2、ROBINS-I和JBI批判性评价工具评估偏倚风险,并进行定性和定量分析。
- 共纳入24项符合条件的研究:5项牙科技术、12项病例报告、1项随机对照研究、2项横断面研究和4项交叉研究。
主要发现
- 研究报告了半数字化路径、直接扫描、间接扫描、编码愈合基台和个性化使用扫描杆。
- 直接扫描技术显示明显的软组织塌陷。
- 间接扫描与常规方法可获得相似结果。
局限性
- 证实该发现需通过随机临床试验进行定量分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurately replicating the emergence profile (EP) of conditioned soft tissue is pivotal for the success of implant-supported restorations. In the field of digital technology, various methods have emerged to capture EP. This review aims to critically assess current digital methodologies for capturing peri-implant EP. MATERIAL AND METHODS: Prospective interventional or observational clinical studies focusing on digitally mapping the emergence profile (EP) around single implant-supported restorations were included. Systematic reviews, in vitro and animal studies, and those not emphasizing EP capture were excluded. A systematic search across four databases (MEDLINE, CENTRAL, Embase, Web of Science) was conducted on 7th August 2024 based on a previously registered protocol (PROSPERO registration number: CRD42023459484). Risk of bias was assessed with RoB 2, ROBINS-I, and JBI critical appraisal tools. Qualitative and quantitative analyses were carried out. RESULTS: Twenty-four eligible studies were identified, comprising 5 dental techniques, 12 case reports, 1 randomized controlled study, 2 cross-sectional studies, and 4 cross-over studies. The studies reported semi-digital pathways, direct scanning, indirect scanning, coded-healing abutments, and individualized use of scan bodies. Notably, the direct scanning technique showed considerable soft tissue collapse. Similar results can be achieved with indirect scanning and the conventional method. CONCLUSIONS: Indirect EP scanning appears as the most promising method for capturing peri-implant EP. However, a confirmation of this finding requires a quantitative analysis through randomized clinical trials.
引用
- Mikulás K, Qian X, Tajti P, et al. Accuracy of Digital Impression Methods for Capturing the Peri-Implant Emergence Profile: A Systematic Review. Clin Oral Implants Res. 2025. PMID: 40219691. doi:10.1111/clr.14441
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。