这项随机对照试验纳入28例因第一乳磨牙早失需保持间隙的患儿,分为3D打印组15例和切削组13例,分别制作金属和复合树脂功能性间隙保持器,在1、3、6个月随访评估临床效果、最大咬合力和咀嚼功能。结果显示保持器类型影响临床评估程度(p<0.001),3D打印金属保持器在6个月随访中表现优于切削复合树脂保持器,两种保持器在最大咬合力上无显著差异,咀嚼功能均有显著改善。

要点

  • 3D打印金属保持器在6个月临床评估中优于切削复合树脂保持器(p<0.001)。
  • 两种保持器两侧最大咬合力均无显著差异(3D打印p=0.270,切削p=0.765)。
  • 两种保持器放置后咀嚼功能均有显著改善。

核心结论

  • 6个月随访显示3D打印金属保持器优于切削复合树脂保持器,两者在咬合力或咀嚼功能上无显著差异,CAD/CAM技术可能为功能性间隙保持器的制作设定新标准。

研究设计与样本

  • 随机对照试验,纳入28例患者,分为3D打印组15例和切削组13例。
  • 纳入标准为第一乳磨牙因龋病并发症拔除或缺失,且距继承牙萌出时间较长。
  • 保持器采用3D打印金属(Co 69%、Cr 25%、W 9.5%、Mo 3.5%、Si 1%,Scheftner,德国)和切削复合树脂(breCAM.HIPC,Bredent,德国)制作。
  • 在1、3、6个月进行临床检查,并评估最大咬合力和咀嚼功能。

主要发现

  • 随时间推移观察到积极的临床趋势,保持器类型(切削 vs 3D打印)影响临床评估程度(p<0.001)。
  • 两种保持器两侧最大咬合力均无显著差异(3D打印 p=0.270,切削 p=0.765)。
  • 两种保持器放置后咀嚼功能均有显著改善。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Since passive fixed space maintainers do not restore the lost tooth or provide chewing function, this study seeks to assess the effectiveness of an innovative approach for maintaining space following the premature extraction of first primary molars, utilizing functional space maintainers designed with CAD/CAM. METHODS: This randomized controlled trial included 28 patients allocated into two groups (15 in 3D Printing group and 13 in Milling group). The inclusion criteria required extraction or loss of the first primary molar due to complications of caries, with a prolonged period until eruption of the successor. Space maintainers were fabricated using 3D printing metal (Co 69 %, Cr 25 %, W 9.5 %, Mo 3.5 %, Si 1 %, Scheftner, Germany) and milling composite (breCAM.HIPC, Bredent, Germany). This study evaluated the efficiency of space maintainers through clinical check-ups at one, three, and six months, maximum occlusal bite force, and masticatory performance assessments. RESULTS: A positive clinical trend was noted over time, with the "type of space maintainer" factor (Milling vs. 3D Printing) influencing the degree of clinical assessment (p < 0.001). There were no significant differences in maximum occlusal bite force between sides for both types of space maintainers (p = 0.270 for 3D Printing and p = 0.765 for Milling). Significant improvements were observed in masticatory performance after the placement of both types of space maintainers. CONCLUSION: A six-month follow-up showed that 3D-printed metal outperformed milled composite ones, with no significant differences in bite force or masticatory performance, indicating that CAD/CAM technology could set new standards in producing functional space maintainers. CLINICAL SIGNIFICANCE: This study underscores the potential of the manufacturing technologies to set new standards in pediatric dentistry, particularly for maintaining space following premature tooth loss, while ensuring improved functional outcomes for young patients.

来源:J Dent,查看原文。版权归原作者所有。