文献速递口腔修复与种植

氧化锆种植体表面纳米结构化以改善临床性能与经济效率——一项关于骨结合的临床前研究

Nano-Structuring of Zirconia Implant Surfaces as an Approach to Improve Clinical Performance and Economic Efficiency-A Preclinical Study on Osseointegration.
PubMed 文献 · Clin Oral Implants Res · 2025-02-24

在羊模型中比较三种纳米结构化氧化锆种植体表面与商用对照表面(ZLA)的骨结合潜力,通过影像学平均骨变化(MBC)和组织形态学分析评估4周与8周结果。总体MBC从植入到4周(0.9 mm ± 0.8 mm)至8周(1.3 mm ± 0.7 mm)增加(p = 0.009),组间无显著差异;微结构对照表面的骨-种植体接触(BIC)在两个时间点均高于纳米结构化表面。作者认为BIC更依赖微米级而非纳米级表面粗糙度,纳米结构化表面可能是临床应用的选项,但需使用负载种植体进一步研究。

要点

  • 羊模型中总体平均骨变化从植入到4周(0.9 mm ± 0.8 mm)至8周(1.3 mm ± 0.7 mm)增加(p = 0.009),组间无显著差异。
  • 微结构对照表面的骨-种植体接触在两个时间点均高于纳米结构化表面。
  • 所有表面的骨改建相似,并从4周至8周增加。

核心结论

  • 羊模型中骨-种植体接触更依赖微米级而非纳米级表面粗糙度,本实验设置下骨改建未受表面形貌影响。
  • 纳米结构化氧化锆表面可能是临床应用的选项,但需使用负载种植体进一步研究以明确BIC是否足以实现长期稳定。

研究设计与样本

  • 临床前动物研究,在羊模型中比较三种纳米结构化氧化锆种植体表面与商用对照表面(ZLA)。
  • 通过影像学测量平均骨变化(MBC)并在4周和8周进行组织形态学分析评估骨结合。
  • 影像学和组织形态学测量采用Kruskal-Wallis方差分析检验表面和时间点的效应(α = 0.05)。

主要发现

  • 总体MBC从种植体植入到4周为0.9 mm ± 0.8 mm,至8周为1.3 mm ± 0.7 mm(p = 0.009),组间无显著差异。
  • 组织学评估显示微结构对照表面的骨-种植体接触(BIC)在两个时间点均高于纳米结构化表面。
  • 所有表面的骨改建相似,并从4周至8周增加。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需使用负载种植体进一步研究以明确BIC是否足以实现长期稳定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Nano-structuring of zirconia dental implants would simplify the production process compared to the currently applied sandblasting and etching. Prior in vitro studies even revealed faster cell spreading and increased viability of osteoblasts on nano-structured zirconia surfaces. The objective was to evaluate the osseointegration potential of nano-structured zirconia implants in a sheep model. MATERIAL AND METHODS: Three different nano-structured surfaces were compared to a commercially available control (ZLA) by measuring the mean bone change (MBC) in radiographs and by histomorphometric analysis after 4 and 8 weeks in sheep. Radiographic and histomorphometric measurements were subjected to Kruskal-Wallis ANOVAs to test the effects of surface and time point (α = 0.05). RESULTS: The overall MBC increased from implant placement to 4 (0.9 mm ± 0.8 mm) to 8 weeks (1.3 mm ± 0.7 mm) (p = 0.009) with no significant differences between the groups. Histological assessment revealed that bone-to-implant contact (BIC) was increased for the micro-structured control surface compared with the nano-structured surfaces at both time points. Bone remodeling was similar for all surfaces and increased from 4 to 8 weeks. CONCLUSIONS: BIC in the sheep model is more dependent on surface roughness on a micro- than nano-structured level, while bone remodeling in the present setup was not influenced by surface topography. Nano-structured zirconia surfaces may be an option for clinical application; however, further research using loaded implants is needed to clarify whether BIC is sufficient to achieve long-term stability.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Rohr N, Permuy M, Fischer C, et al. Nano-Structuring of Zirconia Implant Surfaces as an Approach to Improve Clinical Performance and Economic Efficiency-A Preclinical Study on Osseointegration. Clin Oral Implants Res. 2025. PMID: 39991951. doi:10.1111/clr.14422

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。