新型机器人辅助系统与动态导航系统在牙种植体植入中的精度:一项临床回顾性研究

Accuracy of a Novel Robot-Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study.
PubMed 文献 · Clin Oral Implants Res · 2025-02-15

本临床回顾性研究比较半自主机器人辅助手术系统(sa-RASS)与动态导航系统(DNS)在单颗牙种植体植入中的偏差。分析2023年1月至12月病历,共57例患者(57枚种植体),sa-RASS组29枚、DNS组28枚。sa-RASS组平台和根尖偏差小于DNS组,角度偏差两组无显著差异;不同种植区域和种植体长度间精度无显著差异。

要点

  • sa-RASS组平台偏差0.91±0.46 mm,DNS组1.26±0.51 mm,差异有统计学意义(p<0.001)。
  • sa-RASS组根尖偏差1.06±0.60 mm,DNS组1.51±0.56 mm,差异有统计学意义(p<0.001)。
  • 角度偏差sa-RASS组3.07°±1.66° vs DNS组3.71°±1.64°,差异无统计学意义(p>0.05)。

核心结论

  • 本研究中,sa-RASS种植体植入在平台和根尖偏差方面显示比DNS植入更好的位置精度,尽管这些精度提升的临床相关性可能有限,提示sa-RASS可能在牙种植手术中有优势。

研究设计与样本

  • 临床回顾性研究,回顾分析2023年1月至12月病历,比较sa-RASS与DNS在部分无牙颌患者中基于锥形束CT的种植精度。
  • 共分析57例患者(57枚种植体):sa-RASS组29例(29枚种植体),DNS组28例(28枚种植体)。
  • 测量并分析平台、根尖和角度偏差;使用Kolmogorov-Smirnov检验检查数据分布,并酌情使用t检验或Mann-Whitney U检验。

主要发现

  • 平台偏差sa-RASS组0.91±0.46 mm vs DNS组1.26±0.51 mm(p<0.001)。
  • 根尖偏差sa-RASS组1.06±0.60 mm vs DNS组1.51±0.56 mm(p<0.001)。
  • 角度偏差sa-RASS组3.07°±1.66° vs DNS组3.71°±1.64°(p>0.05)。
  • 不同种植区域(前磨牙、磨牙、上颌、下颌)或种植体长度的精度无显著差异(p>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: This clinical retrospective study aimed to compare the deviations in single-tooth implant placement using novel semi-autonomous robotic-assisted surgery system (sa-RASS) and dynamic navigation system (DNS) methods. MATERIALS AND METHODS: A retrospective analysis of medical records from January to December 2023 was conducted to compare the implantation accuracy of the sa-RASS and DNS in partially edentulous patients using cone-beam computed tomography. Platform, apex, and angular deviations were measured and analyzed. The Kolmogorov-Smirnov test was used to check the data distribution, along with t-tests or Mann-Whitney U-tests, where appropriate. RESULTS: Fifty-seven patients (57 implants) were analyzed: 29 (29 implants) in the sa-RASS group and 28 (28 implants) in the DNS group. The comparison of platform, apex, and angular deviation between the sa-RASS group and DNS group were 0.91 ± 0.46 mm vs. 1.26 ± 0.51 mm (p < 0.001), 1.06 ± 0.60 mm vs. 1.51 ± 0.56 mm (p < 0.001), and 3.07° ± 1.66° vs. 3.71° ± 1.64° (p > 0.05), respectively. In addition, there was no significant difference in the accuracy of different implant regions (premolar, molar, maxilla, and mandible) or implant length (p > 0.05). CONCLUSIONS: In the present study, sa-RASS implant placement showed better positional accuracy than DNS implant placement in platform and apex deviation, although these improvements in accuracy may have limited clinical relevance, suggesting that the sa-RASS might be advantageous in dental implant surgery. TRIAL REGISTRATION: ClinicalTrials.gov identifier: ChiCTR2400085089.