文献速递牙体牙髓病口腔修复与种植

迭代重建锥形束CT在金属伪影存在下检测牙根纵裂的诊断效能

Diagnostic Performance of Iterative Reconstruction of Cone-beam Computed Tomography for Detecting Vertical Root Fractures in the Presence of Metal Artifacts.
PubMed 文献 · J Endod · 2025-02-21

这项离体研究将22颗单根牙(10颗纵裂、12颗无纵裂)置于人类下颌骨模型,用Midmark EIOS锥形束CT分别以滤波反投影(FBP)和迭代重建(IR)重建,并开关金属伪影减少(MAR)工具,比较5名口腔放射医师对牙根纵裂的诊断效能。结果显示重建方法对诊断准确性无显著影响(P > .05),但MAR在FBP结合牙胶时降低敏感度(P < .05)。

要点

  • IR与FBP在牙根纵裂检测上的诊断准确性无显著差异(P > .05)。
  • MAR在FBP结合牙胶时降低敏感度(P < .05),其余条件下敏感度和特异度无显著影响。
  • 牙胶和邻近种植体的金属伪影对牙根纵裂检测有负面影响。

核心结论

  • 重建方法未显著影响牙根纵裂检测,提示两种方法均可用于临床实践而不损害诊断准确性,即使存在金属伪影。

研究设计与样本

  • 离体研究,纳入22颗单根牙(10颗纵裂、12颗无纵裂),置于人类下颌骨模型中。
  • 使用Midmark EIOS锥形束CT扫描,分别采用滤波反投影(FBP)和迭代重建(IR),并开关金属伪影减少(MAR)工具。
  • 临床条件包括牙胶和邻近钛种植体的存在与否。
  • 由5名口腔放射医师采用5分制量表评估匿名图像中牙根纵裂的存在。

主要发现

  • 曲线下面积(AUC)范围为0.60至0.85,重建方法之间无显著差异(P > .05)。
  • 敏感度和特异度一般不受重建方法或MAR激活的影响(P > .05),例外是MAR在FBP结合牙胶时降低敏感度(P < .05)。
  • 牙胶和种植体的金属伪影对牙根纵裂检测有负面影响。

关键数值与推荐

  • AUC范围为0.60至0.85。
  • 重建方法之间无显著差异(P > .05)。
  • MAR在FBP结合牙胶时降低敏感度(P < .05)。

临床怎么用

  • 重建方法未显著影响牙根纵裂检测,提示两种方法均可用于临床实践而不损害诊断准确性,即使存在金属伪影。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Vertical root fractures (VRFs) are challenging to detect, especially in endodontically treated teeth. Cone-beam computed tomography (CBCT) has improved VRF detection over periapical radiography but is limited by metal artifacts. Iterative Reconstruction (IR) algorithms are an alternative to the traditional Filtered-Back Projection (FBP) and have been shown to reduce image noise due to metal artifacts. This study aimed to evaluate the impact of IR on VRF detection in the presence of metal artifacts from intracanal materials and/or adjacent implants. METHODS: This ex-vivo study included 22 single-rooted teeth (10 fractured, 12 nonfractured) placed in a human mandible phantom. CBCT scans were performed using Midmark EIOS CBCT with both reconstruction methods (FBP and IR), with and without metal artifact reduction (MAR) tool activation. Clinical conditions included the presence or absence of gutta-percha and adjacent titanium dental implants. Five oral radiologists evaluated the anonymized images for VRF presence using a 5-point scale. Diagnostic accuracy, sensitivity, specificity, and intra- and interobserver agreement were assessed using receiver operating characteristic curves and multiway ANOVA. RESULTS: The area under the curve values ranged from 0.60 to 0.85, with no significant differences between reconstruction methods (P > .05). Sensitivity and specificity were generally unaffected by reconstruction method or MAR activation (P > .05), except when MAR reduced sensitivity in FBP with gutta-percha (P < .05). Metal artifacts from gutta-percha and implants negatively impacted VRF detection. CONCLUSIONS: The reconstruction method did not significantly influence VRF detection, suggesting that either method can be used in clinical practice without compromising diagnostic accuracy, even in the presence of metal artifacts.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Barros-Costa M, Santaella G, Oliveira-Santos C, et al. Diagnostic Performance of Iterative Reconstruction of Cone-beam Computed Tomography for Detecting Vertical Root Fractures in the Presence of Metal Artifacts. J Endod. 2025. PMID: 39987967. doi:10.1016/j.joen.2025.02.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。