文献速递牙体牙髓病

延长使用时间的XP-Endo Shaper锉与R40 Blue锉在卵圆形根管中的成形能力:对侧前磨牙的微计算机断层扫描研究

Shaping Ability of XP-Endo Shaper Files With Extended Use Time and R40 Blue in Oval Canals: A Microcomputed Tomography Study in Contralateral Premolars.
PubMed 文献 · J Endod · 2025-01-13

本研究采用微计算机断层扫描(micro-CT)比较延长工作时间的单锉XP-endo Shaper(XP-S)系统与Reciproc Blue 40/.06(REC)器械在卵圆形根管中的成形能力。11对单根管对侧前磨牙分为XP-S组(额外增加45秒器械操作)与REC组(每组n=11)。结果显示REC组在根尖区预备的根管壁更多、牙本质保存更好。

要点

  • 两组预备后各截面所有检测参数均较预备前显著改变(P组内≤0.003)。
  • 两组在根管中心定位、10 mm与4 mm处体积或表面积增加、10 mm处未预备根管壁数目上无显著差异。
  • REC组在关键根尖区未预备根管壁减少更多(P组间=0.047)。

核心结论

  • REC器械比XP-S系统预备了更多的根管壁,并在根尖区保留了更多牙本质。

研究设计与样本

  • 体外微计算机断层扫描研究,11对单根管对侧前磨牙按根管预备方案分为XP-S组(额外增加45秒器械操作)与REC组,每组n=11。

主要发现

  • 两组根管预备后所有评估截面的全部检测参数均显著改变(P组内≤0.003)。
  • 两组在根管中心定位、10 mm与4 mm处体积或表面积增加、10 mm处未预备根管壁数目上均无显著差异。
  • REC组在关键根尖区未预备根管壁减少更多(P组间=0.047)。
  • XP-S组在距根尖孔1 mm处近中(P组间=0.007)与远中(P组间=0.028)牙本质厚度减少更多。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study evaluated the shaping ability of the single-file XP-endo Shaper (XP-S) system, employing an extended working time, and the Reciproc Blue number 40/.06 (REC) instrument during the preparation of oval-shaped canals. METHODS: Eleven pairs of contralateral premolars with a single canal were divided into two groups (n = 11) according to the canal preparation protocol: XP-S (with an additional 45 seconds of instrumentation) and REC. Microcomputed tomography images captured before and after preparation were analyzed to assess morphometric measurements (prepared volume/area and unprepared canal walls at 10 mm and 4 mm from the foramen), centroid deviation (at 10 mm), dentin thickness with mesial or distal deviation, and canal-to-root ratio (at 1, 5, and 10 mm from the foramen). RESULTS: In both groups, root canal preparation significantly altered all tested parameters across all evaluated cross-sections (PIntra ≤ 0.003). No significant differences were observed between the groups in canal centralization, volume or surface area increase at 10 mm or 4 mm, nor in the number of unprepared canal walls at 10 mm. However, the REC system showed a greater reduction in unprepared walls in the critical apical zone (PInter = 0.047). The XP-S group exhibited greater reductions in mesial (PInter = 0.007) and distal (PInter = 0.028) dentin thickness at 1 mm from the foramen. CONCLUSIONS: The REC instrument prepared more root canal walls than the XP-S system and promoted greater dentin preservation in the apical zone.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Fontes LP, Cândido FG, Marceliano-Alves MFV, et al. Shaping Ability of XP-Endo Shaper Files With Extended Use Time and R40 Blue in Oval Canals: A Microcomputed Tomography Study in Contralateral Premolars. J Endod. 2025. PMID: 39814136. doi:10.1016/j.joen.2025.01.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。