文献速递牙体牙髓病

定量光诱导荧光(QLF)装置定量值用于裂纹牙牙髓诊断的有效性

Validity of quantitative values of quantitative light-induced fluorescent (QLF) device for pulp diagnosis of teeth with cracks.
PubMed 文献 · J Dent · 2025-01-16

本研究对76颗裂纹牙按美国牙髓病协会指南行牙髓诊断并采集QLF图像,用CrazeLineWizard01软件分析裂纹线定量值,评估其与牙髓诊断的相关性及预测价值。结果显示ΔF和ΔFmax随牙髓病进展而降低、ΔR和ΔRmax升高,不可逆性牙髓炎与牙髓坏死间差异有统计学意义(p<0.05),预测准确率可逆性牙髓炎最高达82.1%、不可逆性牙髓炎73.1%、牙髓坏死约80.0%。作者认为QLF定量值有预测裂纹所致牙髓病严重程度的潜力。

要点

  • 裂纹牙中ΔF和ΔFmax随牙髓病进展而降低,ΔR和ΔRmax升高。
  • 不可逆性牙髓炎与牙髓坏死之间QLF定量值差异有统计学意义(p<0.05)。
  • 基于QLF定量值多项逻辑回归预测牙髓诊断的准确率:可逆性牙髓炎最高达82.1%,不可逆性牙髓炎73.1%,牙髓坏死约80.0%。

核心结论

  • QLF装置的定量值显示出预测裂纹所致牙髓病严重程度的潜力。

研究设计与样本

  • 对76颗裂纹牙按美国牙髓病协会指南行牙髓诊断并采集QLF图像,用QLF软件CrazeLineWizard01定量分析裂纹线。
  • 采用单因素方差分析比较不同牙髓诊断下的QLF定量值,并行多项逻辑回归分析计算QLF定量值对牙髓诊断的预测,用Pearson相关系数比较预测与临床牙髓诊断的相关性。

主要发现

  • 裂纹牙中ΔF和ΔFmax随牙髓病进展而降低,ΔR和ΔRmax升高。
  • 不可逆性牙髓炎与牙髓坏死之间差异有统计学意义(p<0.05)。
  • 基于QLF定量值多项逻辑回归的预测牙髓诊断与临床牙髓诊断的Pearson相关系数为0.699至0.806。
  • 预测准确率:可逆性牙髓炎最高达82.1%,不可逆性牙髓炎73.1%,牙髓坏死约80.0%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The Quantitative Light-Induced Fluorescence (QLF) device provides both the visual information of crack lines on tooth surfaces and quantitative values for fluorescence reactions. The aim of this study was to evaluate the correlation and assess the usefulness of QLF quantitative values in pulp diagnosis of teeth with cracks. METHODS: Pulp diagnosis was performed on 76 teeth with cracks according to the American Association of Endodontics's guidelines, and their QLF images were captured. The crack lines of the QLF images were quantitatively analyzed using the QLF software CrazeLineWizard01. QLF quantitative values (ΔF: fluorescence loss unit, ΔFmax: maximum of fluorescence loss unit, ΔR: red fluorescence gain unit, ΔRmax: maximum of red fluorescence gain unit) according to the pulp diagnosis of teeth with cracks were analyzed using one-way ANOVA. Multinomial logistic regression analysis was conducted to calculate the prediction of pulp diagnosis on QLF quantitative values. The correlation between the predicted pulp diagnosis and the clinical pulp diagnosis was compared using Pearson's correlation coefficient. RESULTS: ΔF and ΔF max decreased with the progression of pulp disease in cracked teeth, while ΔR and ΔR max increased. Significant differences were found between irreversible pulpitis and pulp necrosis (p < 0.05). Pearson correlation coefficients between predicted and clinical pulp diagnosis based on multinomial logistic regression analysis of QLF quantitative values ranged from 0.699 to 0.806. The accuracy of predictionwas up to 82.1 % for reversible pulpitis, 73.1 % for irreversible pulpitis, and approximately 80.0 % for pulp necrosis. CONCLUSIONS: The quantitative values from the QLF device demonstrate its potential for predicting the severity of pulp disease caused by tooth cracks. CLINICAL SIGNIFICANCE: The quantitative values of QLF images acquired with a QLF device, which provide visual information on crack lines of teeth through fluorescence reactions on the tooth surface, showed a significant correlation and predictive value for pulp diagnosis as pulp disease progressed in teeth with cracks.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Son SA, Park SW, Jung YH, et al. Validity of quantitative values of quantitative light-induced fluorescent (QLF) device for pulp diagnosis of teeth with cracks. J Dent. 2025. PMID: 39826610. doi:10.1016/j.jdent.2025.105579

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。