文献速递牙体牙髓病

靶向牙髓进入预备:网格引导与徒手锥形束CT技术的比较

Targeted Endodontic Access Preparation: Comparing Grid-guided and Freehand Cone-beam Computed Tomography Techniques.
PubMed 文献 · J Endod · 2025-01-13

本研究将20颗离体上颌磨牙随机分为CBCT徒手组与网格引导组,比较靶向进入预备的精度与耗时。网格引导组偏离预计划路径的中位数为0.3毫米,显著小于徒手组的0.95毫米(P=0.00001),但操作时间显著更长(417秒,P=0.00008)。作者认为网格引导技术是实现难以到达根管口靶向进入的可行且准确的方法,尚需进一步研究评估其临床应用。

要点

  • 网格引导组偏离预计划路径中位数0.3毫米,显著小于徒手组0.95毫米(P=0.00001)。
  • 网格引导组操作时间417秒,显著长于徒手组(P=0.00008)。
  • 作者认为网格引导技术可行且准确,尚需进一步研究评估临床应用。

核心结论

  • 网格引导技术是实现难以到达根管口靶向进入的可行且准确的方法。
  • 尚需进一步研究评估网格引导技术在临床环境中的应用。

研究设计与样本

  • 将20颗离体上颌磨牙安装于TrueJaw上颌模型(PlanB Dental,Goleta,CA)。
  • 为模拟广泛修复或牙髓腔钙化的临床场景,将堆塑材料有意直接放置在根管口上方。
  • 每颗牙预备为氧化锆冠并粘接就位后,随机分配至CBCT徒手组或网格引导组。
  • 术前拍摄CBCT确定预计划钻针路径,术后拍摄CBCT并与术前扫描重叠。
  • 评估因素包括偏离预计划钻针路径的偏差、操作时间及必要的调整。

主要发现

  • 网格引导技术偏离预计划进入目标的中位数为0.3毫米,显著小于徒手技术的中位数0.95毫米(P=0.00001)。
  • 网格引导方法所需操作时间为417秒,显著多于徒手方法(P=0.00008)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文指出尚需进一步研究评估网格引导技术在临床环境中的应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Endodontic access is often one of the most challenging aspects of treatment, particularly in cases involving locating calcified or missed canals, or when performing selective retreatments of a targeted root. Therefore, the purpose of this study is to compare the accuracy of targeted accesses made using prefabricated grid to those made using freehand techniques with cone-beam computed tomography (CBCT) measurements. METHODS: Twenty extracted maxillary molars were mounted into the TrueJaw maxillary model (PlanB Dental, Goleta, CA). To replicate a clinical scenario where the tooth is extensively restored or has a calcified pulp chamber, the build-up material was intentionally placed directly over the canal orifices. Each of the teeth were prepared for zirconia crowns and once fabricated, these crowns were cemented. The teeth were randomly assigned to either the CBCT freehanded group or the grid-guided group. Preoperative CBCT scans were taken to determine the preplanned drill path, and these scans were superimposed on the postoperative CBCT's taken after the targeted access was completed. The factors evaluated included deviations from the preplanned drill path, procedural times, and adjustments if necessary. RESULTS: The grid-guided technique achieved a significantly smaller deviation from the planned access target (median 0.3 mm) compared to the freehand technique (median 0.95 mm, P = .00001). However, the grid-guided approach required significantly more procedural time (417 seconds) than the freehand method (P = .00008). CONCLUSION: The grid-guided technique is a viable and accurate method for achieving targeted access to hard-to-reach canal orifices. Further studies are needed to evaluate its application in clinical settings.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Rezaei G, Khalilkhani KN, Daghighi K, et al. Targeted Endodontic Access Preparation: Comparing Grid-guided and Freehand Cone-beam Computed Tomography Techniques. J Endod. 2025. PMID: 39814133. doi:10.1016/j.joen.2025.01.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。