CAD/CAM基台形态对种植体治疗结局的影响:一项随机对照试验
这项随机对照试验比较了CAD/CAM氧化锆基台(凹形与线性发散形穿黏膜形态)对上颌前牙区种植体支持修复体戴入后1年种植体周围黏膜动态及健康指标的影响。54例完成研究(凹形组29例,线性发散组25例)。两组种植体存活率均为100%,修复体存留率98.2%,两组均观察到颊侧黏膜顶点冠向迁移、黏膜厚度增加及探诊深度和探诊出血增加的趋势,但临床可忽略,两组间无实质差异。
要点
- 凹形与线性发散形CAD/CAM氧化锆基台在1年随访中种植体存活率均为100%,修复体存留率98.2%
- 两组均观察到颊侧黏膜顶点冠向迁移、黏膜厚度增加及探诊深度和探诊出血增加的趋势,但临床可忽略
- 无论穿黏膜基台形态如何变化,两组间均未观察到实质性差异
核心结论
- 使用线性发散形或凹形定制CAD/CAM氧化锆基台,采用螺丝固位、延迟加载方式,未产生显著差异。
研究设计与样本
- 随机对照试验,计算机引导下植入种植体并完成骨结合后,将受试者随机分为实验组(凹形形态)和对照组(线性发散形态)。
- 共招募60例受试者,54例完成研究(实验组凹形29例,对照组25例)。
- 在最终修复体戴入后1年内的不同时间点评估种植体周围软组织动态、表型特征及种植体周围健康指标。
主要发现
- 从终印模到12个月,总体种植体存活率为100%,修复体存留率为98.2%。
- 两组均观察到颊侧黏膜顶点冠向迁移、黏膜厚度增加以及探诊深度和探诊出血增加的趋势,但这些变化临床可忽略。
- 无论穿黏膜基台形态如何变化,研究组间未观察到实质性差异。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Variations in transmucosal abutment contour design may affect the outcomes of implant therapy. This randomized controlled trial was primarily aimed at testing the effect that CAD/CAM zirconia abutments with either a concave or linear divergent transmucosal morphology have on peri-implant mucosal dynamics and indicators of peri-implant health at 1 year after final implant-supported prosthesis insertion in the anterior maxilla. MATERIALS AND METHODS: Following computer-guided implant placement and osseointegration, eligible subjects were randomized into either the experimental (concave morphology) or the control (linear divergent morphology) group. A comprehensive set of outcomes of interest related to peri-implant soft tissue dynamics, phenotypical features, and indicators of peri-implant health were assessed at different time points over a 1-year period after insertion of the final restoration. RESULTS: Out of 60 initially recruited subjects, a total of 54 completed the study (n = 29 in the experimental group concave/n = 25 in the control group). Overall implant survival and restoration rates between master impression and 12 months were 100% and 98.2%, respectively. Although a trend for coronal migration of the buccal mucosa zenith, gain in mucosal thickness, and increased probing depth and bleeding on probing was observed in both groups, these changes were clinically negligible, and no substantial differences were observed between study groups regardless of variations in transmucosal abutment morphology. CONCLUSION: The use of either linear divergent or concave custom CAD/CAM zirconia abutments in a screw-retained, delayed loading approach yielded no significant differences.
引用
- Barwacz CA, Swenson M, Couso-Queiruga E, et al. Effect of CAD/CAM Abutment Morphology on the Outcomes of Implant Therapy: A Randomized Controlled Trial. Clin Oral Implants Res. 2024. PMID: 39641983. doi:10.1111/clr.14389
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。