激光激活与声波激活冲洗在保守器械预备根管中去除碎屑的效果比较
本研究采用微计算机断层扫描分析,比较激光激活与声波激活冲洗在下颌磨牙近中根管系统中去除碎屑的效果。结果显示激光组空气填充体积平均增加百分比为37.4%,显著高于声波组的20.2%(P < .05),表明激光激活冲洗在保守器械预备根管系统中去除碎屑更有效,但研究局限性提示需进一步评估其对临床结局的影响。
要点
- 激光激活冲洗去除碎屑效果优于声波激活冲洗。
- 激光组空气填充体积平均增加37.4%,声波组为20.2%。
- 差异有统计学意义(P < .05),但需进一步临床研究。
核心结论
- 在保守器械预备的根管系统中,激光激活冲洗去除碎屑的效果显著优于声波激活冲洗。
主要发现
- 激光组空气填充体积平均增加百分比为37.4%,声波组为20.2%。
- 两组差异有统计学意义(P < .05)。
关键数值与推荐
- 根管最小器械预备至最大根尖锉尺寸20/06v(DCTaper,SSWhite,NJ)。
- 声波组使用SmartLite Pro EndoActivator(Dentsply Tulsa,OK)配15/02尖。
- 激光组使用WaterLase iPlus(Biolase,CA)配RFT2尖。
- 两组激活时间和冲洗液体积相同。
临床怎么用
- 在保守器械预备的根管中,可优先考虑激光激活冲洗以增强碎屑去除。
- 需注意研究局限性,激光激活冲洗对临床结局的影响尚需进一步研究。
局限性
- 研究为离体牙实验,结果需临床研究验证。
- 作者指出由于研究局限性,需进一步评估激光激活冲洗对临床结局的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: To compare the efficacy of laser activated and sonic activated irrigation on the removal of debris in mesial root canal systems of mandibular molars using micro-computed tomographic analysis. METHODS: Forty-eight mesial roots of extracted mandibular molars with isthmus were selected and randomly allocated into 2 groups: Sonic Group and Laser Group. The root canals were minimally instrumented to a maximum apical file size of 20/06v (DCTaper, SSWhite, NJ). The Sonic Group received irrigant activation using the SmartLite Pro EndoActivator (Dentsply Tulsa, OK) with a 15/02 tip. The Laser Group received irrigant activation using the WaterLase iPlus (Biolase, CA) with a RFT2 tip. The teeth were activated for the same time with the same volume of irrigants. Micro-computed tomographic scans were obtained preinstrumentation, preirrigation, and postirrigation. To quantify debris removal, the air-filled volume was measured preirrigation and postirrigation, and the percentage increase in air-filled volume was calculated. Data were analyzed statistically (independent samples t-test, significance set at 5%). RESULTS: The Laser Group demonstrated a significantly higher mean percentage increase in air-filled volume (37.4%) compared to the Sonic Group (20.2%). This difference was statistically significant (P < .05). CONCLUSIONS: The Laser Group was significantly more effective in removing debris compared to the Sonic Group in minimally instrumented root canal systems. However, due to the limitations of this study, further research is needed to assess the impact of laser activated irrigation on clinical outcomes.
引用
- Huynh A, Poly A, Yamaguchi M, et al. Efficacy of Laser Activated versus Sonic Activated Irrigation for Debris Removal in Conservatively Instrumented Root Canals. J Endod. 2024. PMID: 39706474. doi:10.1016/j.joen.2024.12.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。