文献速递牙体牙髓病口腔颌面外科

机器人与动态导航在截骨与根尖切除中的精度与时间对比

Comparing the accuracy and treatment time of a robotic and dynamic navigation system in osteotomy and root-end resection: An in vitro study.
PubMed 文献 · Int Endod J · 2024-12-04

本体外研究用4个3D打印下颌模型比较机器人系统(RS)与动态导航系统(DNS)在截骨和根尖切除中的精度与治疗时间。结果显示RS组全局平台偏差、全局根尖偏差和角度偏转均显著小于DNS组,但注册时间与总手术时间显著更长。

要点

  • RS在截骨与根尖切除中的精度显著优于DNS。
  • RS钻针时间更短,但注册时间与总手术时间更长。
  • RS有望成为牙髓显微外科的可靠技术进展。

核心结论

  • 与DNS相比,RS在截骨和根尖切除中精度更高且钻针时间更短。
  • RS有望成为牙髓显微外科的可靠技术进展,但未来需优先缩短注册时间。

研究设计与样本

  • 体外研究,使用4个3D打印的相同下颌模型,每个模型含18颗牙。
  • 每模型选取35、33、32、42、43、45及36、46的近中颊根进行操作。
  • 术前对所有模型行CBCT与口内扫描,用DentalNavi软件规划钻针路径、深度并设计手术附件。
  • RS组以机器人辅助完成截骨与根尖切除,DNS组以动态导航完成。
  • 术后行CBCT扫描,比较全局平台偏差、全局根尖偏差、角度偏转与时间。

主要发现

  • RS组全局平台偏差、全局根尖偏差和角度偏转均显著小于DNS组(p<.05)。
  • RS组注册时间显著长于DNS组(p<.001),钻针时间显著更短(p<.001)。
  • RS组总手术时间显著长于DNS组(p<.001)。
  • 亚组分析显示,前牙与后牙区RS组根尖偏差和角度偏转均显著小于DNS组(p<.001)。
  • 前牙区DNS组总时间显著短于RS组(p<.01)。

临床怎么用

  • 追求高精度截骨与根尖切除时可考虑机器人系统,但需权衡更长的总手术时间。
  • 应用RS时应优化注册流程以缩短注册时间。

局限性

  • 本研究为体外3D打印模型研究,非临床活体研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the accuracy and treatment time of a robotic system (RS) and a dynamic navigation system (DNS) in osteotomy and root-end resection in an in vitro study. METHODOLOGY: In this study, four identical mandibular models were created using three-dimensional (3D) printing, each model including 18 teeth. In the surgical procedures, teeth #35, #33, #32, #42, #43 and #45, along with the mesiobuccal roots of teeth #36 and #46, were specifically selected for operation on each model. Cone-beam computed tomography (CBCT) and intraoral scans were performed on all models. DentalNavi software was used to plan a drilling path and depth as well as design surgical accessories. In the RS, osteotomy and root-end resection were performed with robotic assistance, whereas in the DNS, these procedures were performed using dynamic navigation. Post-operative CBCT scans were obtained. Global platform deviation, global apex deviation, angular deflection, and time were compared to evaluate the accuracy and treatment time of the surgeries. The treatment time was defined as the registration time and drilling time. Statistical analyses were performed using the Shapiro-Wilk and independent sample t-test. RESULTS: The global platform deviation, global apex deviation and angular deflection in the RS group were significantly smaller than those in the DNS group (p <.05). The registration time in the RS group was significantly longer than that in the DNS group (p <.001), whereas the drilling time was significantly shorter (p <.001). The overall surgical time was significantly longer in the RS group than in the DNS group (p <.001). Subgroup accuracy analysis revealed that in both the anterior and posterior tooth regions, the RS group exhibited significantly smaller apical and angular deviations than the DNS group (p <.001). Additionally, in both the anterior and posterior tooth subgroups, the total time for the DNS group was significantly shorter than that for the RS group in the anterior tooth area (p <.01). CONCLUSIONS: RS showed higher accuracy and shorter drilling time in osteotomy and root-end resection compared to DNS. The RS holds promise as a reliable technological advancement in endodontic microsurgery. However, future endeavours should prioritize the reduction in registration time.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Liu C, Wang X, Liu Y, et al. Comparing the accuracy and treatment time of a robotic and dynamic navigation system in osteotomy and root-end resection: An in vitro study. Int Endod J. 2024. PMID: 39630537. doi:10.1111/iej.14178

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。