CBCT-SAM:一种用于CBCT根尖周病变检测的新型AI模型
本研究使用185例确诊根尖周病变的CBCT扫描训练并验证新型AI模型CBCT-SAM,并与Modified U-Net、PAL-Net等模型比较诊断与分割性能。CBCT-SAM平均诊断准确率达98.92%±10.37%,分割准确率99.65%±0.66%,在分割准确率、敏感性和DSC上显著优于Modified U-Net,与PAL-Net无显著差异。CBCT-SAM可在CBCT根尖周病变识别中提供专家级辅助。
要点
- CBCT-SAM平均诊断准确率98.92%±10.37%,分割准确率99.65%±0.66%。
- CBCT-SAM分割敏感性72.36±21.61%,特异性99.87%±0.11%,DSC 0.70±0.19。
- CBCT-SAM分割准确率、敏感性和DSC显著优于Modified U-Net。
核心结论
- CBCT-SAM能够在CBCT根尖周病变识别中提供专家级辅助。
研究设计与样本
- 使用185例确诊根尖周病变的CBCT扫描进行模型训练与验证,手动分割标签由训练有素的操作者准备并经颌面放射科医师验证。
- 比较四种AI模型:CBCT-SAM、去除渐进预测细化模块(PPR)的CBCT-SAM、Modified U-Net和PAL-Net。
- 诊断性能以准确率评价,分割性能以准确率、敏感性、特异性、精确率和Dice相似系数(DSC)评价。
主要发现
- CBCT-SAM平均诊断准确率为98.92%±10.37%,平均分割准确率为99.65%±0.66%。
- CBCT-SAM平均敏感性为72.36±21.61%,特异性为99.87%±0.11%,精确率为0.73±0.21,DSC为0.70±0.19。
- CBCT-SAM和PAL-Net在分割准确率(p=0.023,p=0.041)、敏感性(p=0.000,p=0.002)和DSC(p=0.001,p=0.004)上显著优于Modified U-Net。
- CBCT-SAM、去除PPR的CBCT-SAM和PAL-Net之间无显著差异;但加入PPR后,CBCT-SAM在诊断和分割任务上略优于PAL-Net。
临床怎么用
- AI辅助CBCT阅片可提高椅旁诊断准确性和效率,减少人为漏诊。
- 有助于根尖周病变的早期发现和治疗。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Periapical lesions are not always evident on radiographic scans. Sometimes, asymptomatic or initial periapical lesions on cone-beam computed tomography (CBCT) could be missed by inexperienced dentists, especially when the scan has a large field of view and is not for endodontic treatment purposes. Previously, numerous algorithms have been introduced to assist radiographic assessment and diagnosis in the field of endodontics. This study aims to investigate the efficacy of CBCT-SAM, a new artificial intelligence (AI) model, in identifying periapical lesions on CBCT. METHODS: Model training and validation in this study was performed using 185 CBCT scans with confirmed periapical lesions. Manual segmentation labels were prepared by a trained operator and validated by a maxillofacial radiologist. The diagnostic and segmentation performances of four AI models were evaluated and compared: CBCT-SAM, CBCT-SAM without progressive Prediction Refinement Module (PPR), and two previously developed models: Modified U-Net and PAL-Net. Accuracy was used to evaluated the diagnostic performance of the models, and accuracy, sensitivity, specificity, precision and Dice Similarity Coefficient (DSC) were used to evaluate the models' segmentation performance. RESULTS: CBCT-SAM achieved an average diagnostic accuracy of 98.92% ± 010.37% and an average segmentation accuracy of 99.65% ± 0.66%. The average sensitivity, specificity, precision and DSC were 72.36 ± 21.61%, 99.87% ± 0.11%, 0.73 ± 0.21 and 0.70 ± 0.19. CBCT-SAM and PAL-Net performed significantly better than Modified U-Net in segmentation accuracy (p = 0.023, p = 0.041), sensitivity (p = 0.000, p = 0.002), and DSC (p= 0.001, p= 0.004). There is no significant difference between CBCT-SAM, CBCT-SAM without PPR and PAL-Net. However, with PPR incorporated into the model, CBCT-SAM slightly surpassed PAL-Net in the diagnostic and segmentation tasks. CONCLUSIONS: CBCT-SAM is capable of providing expert-level assistance in the identification of periapical lesions on CBCT. CLINICAL SIGNIFICANCE: The application of artificial intelligence could increase dentists' chairside diagnostic accuracy and efficiency. By assisting radiographic assessment, such as periapical lesions on CBCT, it helps reduce the chance of missed diagnosis by human errors and facilitates early detection and treatment of dental pathologies at the early stage.
引用
- Chau KK, Zhu M, AlHadidi A, et al. A novel AI model for detecting periapical lesion on CBCT: CBCT-SAM. J Dent. 2024. PMID: 39667487. doi:10.1016/j.jdent.2024.105526
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。