3D打印一体式与分体式正畸透明矫治器附件粘接于临时冠的对比:概念验证
本研究制备60个带附件的临时冠,比较传统Protemp冠粘接附件、3D打印冠粘接附件和3D打印冠一体成型复合附件三种方式,经热循环后测试剪切粘接强度。结果显示3D打印一体成型组强度最高(12.39 ± 1.92 MPa),且热循环后粘接强度无显著下降(P = 0.643),提示该技术适用于需要临时修复的正畸治疗。
要点
- 3D打印一体成型附件临时冠剪切粘接强度最高,达12.39 ± 1.92 MPa。
- 热循环后除3D打印一体成型组外,其余组附件粘接强度均显著下降。
- 粘接组主要失效模式为粘接剂破坏,3D打印组主要为附件断裂。
核心结论
- 3D打印带附件临时冠强度高,适用于需要临时修复的正畸治疗。
- 3D打印一体成型复合附件经热循环后粘接强度无显著变化(P = 0.643)。
研究设计与样本
- 共制备60个带附件的临时冠:20个传统Protemp冠粘接附件,20个3D打印冠粘接附件,20个3D打印冠一体成型复合附件。
- 扫描两颗中切牙(无附件和有附件各一次)制作STL文件用于打印试件。
- 半数试件(30个,每组n = 10)接受5000次热循环。
- 使用万能试验机评估剪切粘接强度(MPa),分析断裂类型。
- 数据分析采用ANOVA和post hoc Tukey检验(α = 0.05)。
主要发现
- 3D打印试件在各组中强度值均高于粘接附件组(P < 0.001)。
- 3D打印带附件冠强度最高(12.39 ± 1.92 MPa)。
- 热循环显著降低附件粘接强度(P < 0.001),但3D打印一体成型复合附件组无显著变化(P = 0.643)。
- 粘接附件组主要失效模式为粘接剂类型破坏,3D打印组主要失效模式为附件断裂。
临床怎么用
- 在需要临时修复的正畸治疗中,可考虑采用3D打印一体成型附件临时冠。
- 该技术可整合入数字化正畸治疗流程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aimed to introduce a novel technique for fabricating provisional crowns integrated as a single unit with aligner attachments. METHODS: A total of 60 crowns with attachments were prepared: 20 conventional (Protemp) and 40 3D-printed (20 bonded with attachments; 20 integrated with composite attachments as a single unit) using NextDent resin. Two central incisors were scanned (once without attachments and once with attachments) to create STL files for specimen printing. Half of the specimens (30, n = 10 per group) underwent thermal cycling (5000 cycles). Shear bond strengths (MPa) were evaluated using a universal testing machine. The debonded areas and attachment failures were analyzed to determine the fracture type. Data analyses were performed using ANOVA and post hoc Tukey tests (α = 0.05). RESULTS: The 3D-printed specimens showed higher strength values than the bonded attachments per group (P < 0.001). The 3D-printed crowns with attachments demonstrated the highest strength (12.39 ± 1.92 MPa). Thermal cycling significantly decreased the bond strength of the attachments (P < 0.001), except in the 3D-printed crowns with composite attachments as a single unit, which showed no significant change after thermal cycling (P = 0.643). In the bonded attachment groups, the adhesive type was the predominant failure mode, while in the 3D-printed groups, attachment fractures were the primary cause of failure. CONCLUSION: The 3D-printed provisional crowns with attachments have high strength and is clinically appropriate for orthodontic treatment when temporization of teeth is indicated. CLINICAL SIGNIFICANCE: The developed technique for fabricating 3D-printed provisional restorations with orthodontics attachments as a single unit is a promising approach. The technique may be incorporated into the digital orthodontic treatment workflow when temporization is indicated.
引用
- Shahin SY, Nassar EA, Gad MM, et al. 3D-printed one-piece versus two-piece orthodontic clear aligner attachments bonded with provisional crowns: A proof of concept. J Dent. 2024. PMID: 39427961. doi:10.1016/j.jdent.2024.105406
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。