动态计算机辅助种植手术在全口无牙颌患者中的精度:一项体外研究
该体外研究将12个全口无牙上颌模型分为微螺钉示踪组和骨示踪组,使用X-Guide动态计算机辅助种植手术系统各植入6枚种植体,比较两种配准方法的种植精度与时间效率。结果显示微螺钉示踪组在角度偏差、三维平台偏差、二维平台偏差和三维根尖偏差上均显著低于骨示踪组,骨示踪配准耗时显著更长,但整体手术时间两组相似。
要点
- 微螺钉示踪配准较骨示踪配准显著提高无牙颌种植体植入精度。
- 骨示踪配准耗时显著长于微螺钉配准,但整体手术时间无显著差异。
- 该结论来自体外模型研究,临床转化需进一步验证。
核心结论
- 在无牙颌模型中,微螺钉示踪配准较骨示踪配准可提高动态计算机辅助种植手术的种植体植入精度,并略微缩短整体手术时间。
主要发现
- 微螺钉示踪组角度偏差均值差为-3.33°(95%CI:-6.56至-0.09;p=0.044),显著低于骨示踪组。
- 微螺钉示踪组三维平台偏差均值差为-1.01 mm(95%CI:-1.74至-0.29;p=0.006),显著低于骨示踪组。
- 微螺钉示踪组二维平台偏差均值差为-0.97 mm(95%CI:-1.71至-0.23;p=0.010),显著低于骨示踪组。
- 微螺钉示踪组三维根尖偏差均值差为-1.18 mm(95%CI:-1.92至-0.44;p=0.002),显著低于骨示踪组。
- 整体手术时间两组相似(均值差:6.10 min;95%CI:-0.31至12.51;p=0.06),但骨示踪配准耗时显著更长(均值差:4.79 min;95%CI:2.96至6.62;p<0.05)。
临床怎么用
- 在无牙颌动态计算机辅助种植手术中,可优先考虑微螺钉示踪配准以提高植入精度并减少配准时间。
局限性
- 本研究为体外模型研究,结果需在临床环境中进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To compare miniscrew versus bone tracing registration methods on dental implant placement accuracy and time efficiency in edentulous jaws using a dynamic computer-assisted implant surgery (d-CAIS) system. METHODS: Twelve fully edentulous maxillary models were allocated into two groups: miniscrew tracing (MST) group, where registration was performed by tracing four miniscrews; and bone tracing (BT) group, where registration was conducted by tracing maxillary bone fiducial landmarks. Six implants were placed on each model using the X-Guide® d-CAIS system. Pre- and postoperative cone-beam computed tomography (CBCT) scans were superimposed to evaluate implant placement accuracy. The time required for registration and the overall surgery time were also recorded. RESULTS: Thirty-six implants were placed in each group. The MST group showed significantly lower mean angulation deviations (mean difference (MD): -3.33°; 95 % confidence interval (CI): -6.56 to -0.09); p = 0.044), 3D platform deviations (MD: -1.01 mm; 95 % CI: -1.74 to -0.29; p = 0.006), 2D platform deviations (MD: -0.97 mm; 95 % CI: -1.71 to -0.23; p = 0.010), and 3D apex deviations (MD: -1.18 mm; 95 % CI: -1.92 to -0.44; p = 0.002) versus the BT group. The overall surgery time was similar for both groups (MD: 6.10 min.; 95 % CI: -0.31 to 12.51; p = 0.06), though bone tracing required significantly more time compared with miniscrew registration (MD: 4.79 min.; 95 % CI: 2.96 to 6.62; p < 0.05). CONCLUSIONS: Registration with MST increases the accuracy of implant placement with a d-CAIS system in edentulous jaws compared with the BT method, and slightly reduces the overall surgery time. CLINICAL SIGNIFICANCE: Miniscrew tracing registration improves implant placement accuracy in comparison with bone tracing registration.
引用
- Ruiz-Romero V, Jorba-Garcia A, Camps-Font O, et al. Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study. J Dent. 2024. PMID: 39106900. doi:10.1016/j.jdent.2024.105290
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。