石榴提取物单独或联合氯己定抗口腔多菌种生物膜的效果
本研究在胶原包被羟基磷灰石片上培养来自2名供者的口腔多菌种生物膜,分别培养7天或3周后暴露于水、2% CHX、10%/20%/30% PGE 3分钟,用活死染色共聚焦显微镜评估杀菌比例;30% PGE单独或联合2% CHX抗生物膜效果优于2% CHX。
要点
- 30% PGE对口腔多菌种生物膜的杀菌效果优于2% CHX。
- PGE与2% CHX联用抗生物膜效果亦优于单用CHX。
- 陈旧(3周)菌斑生物膜比7天菌斑更难被杀灭。
核心结论
- 30% PGE单独或联合CHX对羟基磷灰石片上口腔多菌种生物膜的抗生物膜效果优于2% CHX。
研究设计与样本
- 体外研究:石榴皮冻干提取物经UPLC测定punicalagin含量。
- 来自2名供者的口腔多菌种生物膜培养于胶原包被羟基磷灰石片,培养7天或3周。
- 生物膜暴露于水、2% CHX、10%/20%/30% PGE 3分钟;每组扫描20个区域。
主要发现
- 各溶液间生物膜体积无差异(p = .111)。
- PGE杀菌比例随浓度在37%至55.3%之间,30% PGE优于2% CHX(p = .0009)。
- 2% CHX杀菌比例在25.2%至48.7%之间;水为5%至6.7%(p < .00001)。
- 10%与20% PGE为中间值,与30% PGE无显著差异(p = 1.002)。
- PGE单用或联合2% CHX抗生物膜效果优于CHX(p < .05);陈旧菌斑更耐药(p < .05)。
关键数值与推荐
- 杀菌比例:PGE 37%–55.3%,2% CHX 25.2%–48.7%,水5%–6.7%。
- 生物膜体积组间比较p = .111;30% PGE vs 2% CHX p = .0009;水 vs 其他p < .00001。
临床怎么用
- 提示30% PGE可作为口腔抗菌替代或辅助方案的体外依据,但尚需临床验证。
- 对陈旧菌斑需更强或更长干预。
- 联合CHX可能增强抗生物膜效果。
局限性
- 为体外羟基磷灰石片模型,仅2名供者,结果不能直接外推临床。
- 仅评估短期(3分钟)暴露的杀菌比例,未报告长期或毒性数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: Natural bioactive products have been tested as alternative antimicrobial agents. This study evaluated the effect of Punica granatum extract (PGE) on oral multispecies biofilms. METHODOLOGY: Lyophilized extracts from pomegranate peel were prepared, and the punicalagin content was assessed by ultra-performance liquid chromatography (UPLC). Oral multispecies biofilms from 2 donors were grown on four collagen-coated hydroxyapatite discs. After incubation for 7 days or 3 weeks, the biofilms were exposed to water (control), 2% CHX, 10% PGE, 20% PGE or 30% PGE for 3 min. The proportions of dead bacteria were assessed by the live/dead staining and confocal microscopy. After the analysis, the best PGE concentration (30%) was combined with CHX. The experimental phases were repeated using water, 2% CHX, 30% PGE and 30% PGE + 2% CHX. Five random areas of the biofilm on each disc were scanned, resulting in 20 scanned areas for each group. RESULTS: Regarding the biofilm volume, no differences were found amongst solutions (p = .111). The PGE solution killed bacteria effectively in 1-week, 2-week and 3-week-old-plaque biofilms, ranging from 37 to 55.3%, depending on the PGE concentration. The 30% PGE (a) (p = .0009) had greater antibiofilm effectiveness than 2% CHX (b), which killed bacteria in the 25.2 to 48.7% range. The 10% and 20% PGE had intermediate values (ab), without significant differences from 30% PGE (p = 1.002). Water (c) had the lowest proportion of dead bacteria (p < .00001) in a range of 5 to 6.7% and lower effectiveness in killing bacteria (p < .05). The PGE alone or mixed with 2% CHX had greater anti-biofilm effectiveness than CHX (p < .05). The old plaque biofilms were more resistant than the 7-day-old plaque (p < .05). CONCLUSIONS: The 30% PGE (alone or combined with CHX) exhibited a greater antibiofilm effect on oral multispecies biofilms grown on hydroxyapatite discs than 2% CHX.
引用
- Gallas JA, Pelozo LL, Corona SAM, et al. Effect of pomegranate solution alone or combined with chlorhexidine against oral multispecies biofilm. Int Endod J. 2024. PMID: 39126293. doi:10.1111/iej.14135
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。