新型抗菌四氨合氟化铜的研发与性能评价
本研究以氟化铜和氨水溶液合成四氨合氟化铜(CTF)溶液,经X射线光电子能谱表征,并用人脱落乳牙干细胞(SHED)和人牙龈成纤维细胞(HGF-1)评估细胞毒性、离子选择电极测氟浓度、pH电极测碱度。在牙本质块上以变形链球菌评估抗菌与染色性能,与氟化二氨银(SDF)及水对照。结果显示CTF为碱性58%溶液,具生物相容性、抗菌性和非染色性。
要点
- CTF为碱性58%溶液,对SHED和HGF-1的半数抑制浓度分别为195±16 ppm和137±11 ppm。
- CTF氟浓度为121,000±5,000 ppm,pH值为9。
- CTF抗菌效果与SDF相当且优于水,牙本质染色ΔE显著低于SDF。
核心结论
- 本研究成功研制出碱性58%四氨合氟化铜(CTF)溶液,该溶液具有生物相容性、抗菌性和非染色性。
研究设计与样本
- 研究采用氟化铜和氨水溶液合成CTF溶液,以X射线光电子能谱(XPS)进行表征。
- 细胞毒性用人脱落乳牙干细胞(SHED)和人牙龈成纤维细胞(HGF-1)评估,氟浓度用离子选择电极测定,碱度用pH电极测定。
- 人牙本质块经CTF处理后与变形链球菌孵育,以氟化二氨银(SDF)为阳性对照、水为阴性对照,评估抗菌和染色效果。
- 采用菌落形成单位(CFUs)和共聚焦激光扫描显微镜(CLSM)检查生物膜的动力学和活力,用分光光度法评估牙本质染色性能,统计分析采用单因素方差分析和Bonferroni事后检验。
主要发现
- XPS确认了CTF溶液的合成。
- CTF对SHED和HGF-1的半数抑制浓度分别为195±16 ppm和137±11 ppm。
- CTF的氟浓度为121,000±5,000 ppm,pH值为9。
- CTF、SDF和水组的Log10 CFU分别为5.0±0.2、4.9±0.1和7.4±0.1(p < 0.001,CTF、SDF<水)。
- CLSM显示CTF、SDF和水组的死/活比分别为0.8±0.2、0.8±0.2和0.3±0.1(p < 0.001,CTF、SDF>水)。
临床怎么用
- 若CTF成功转化为临床护理,CTF可成为一种简单、可负担的防龋剂,供临床医生预防龋齿。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To develop a novel and biocompatible copper tetraamine fluoride (CTF) with antibacterial and nondiscolouring properties. METHOD: This study used copper fluoride and ammonia solution to develop CTF solution. The CTF was characterized by X-ray photoelectron spectroscopy (XPS). Cytotoxicity was evaluated by stem cells from human exfoliated deciduous teeth (SHED) and human gingival fibroblasts (HGF-1). The fluoride concentration was determined using ion-selective electrode. The alkalinity was measured by a pH electrode. The human dentine blocks were treated with CTF and then incubated with Streptococcus mutans to evaluate the antimicrobial and discolouring effects. The silver diamine fluoride (SDF) was employed as the positive control, and water was the negative control. The colony-forming units (CFUs) and confocal laser scanning microscopy (CLSM) were used to examine the kinetics and viability of the biofilm. The discolouring property on dentine was assessed by spectrophotometry. One-way analysis of variance with the Bonferroni post hoc test was performed to assess and compare the data. RESULTS: XPS confirmed synthesis of CTF solution. The half-maximal inhibitory concentration of CTF on SHED and HGF-1 was 195±16 ppm and 137±11 ppm. The fluoride concentration was 121,000±5,000 ppm. The pH value was 9. Log10 CFU of the CTF, SDF and water group were 5.0 ± 0.2, 4.9 ± 0.1 and 7.4 ± 0.1 (p < 0.001, CTF, SDF<Water). CLSM showed that the dead-to-live ratio of the CTF, SDF and water group were 0.8 ± 0.2, 0.8 ± 0.2, and 0.3 ± 0.1 (p < 0.001, CTF, SDF>Water). Spectrophotometry showed that the ΔE of the CTF, SDF and water group were 5 ± 2, 6 ± 3 and 45±2 (p < 0.001, CTF, Water<SDF). CONCLUSION: This study developed an alkaline 58% CTF solution, which is biocompatible, antibacterial and non-discolouring. CLINICAL SIGNIFICANCE: If CTF is successfully translated into clinical care, CTF can be a simple and affordable anti-caries agent for clinicians to prevent dental caries.
引用
- Xu VW, Yin IX, Niu JY, et al. Developing a novel antibacterial copper tetraamine fluoride. J Dent. 2024. PMID: 39214277. doi:10.1016/j.jdent.2024.105320
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。