下颌覆盖义齿一体式钛锆微型种植体相对位置的CBCT横断面评估

A cross-sectional CBCT assessment of the relative position of one-piece titanium-zirconium mini-implants placed for mandibular overdentures using non-guided surgery.
PubMed 文献 · Clin Oral Implants Res · 2024-07-23

本研究通过CBCT分析73例患者下颌覆盖义齿中四枚一体式钛锆微型种植体的相对位置,测量种植体间及与义齿就位道的角度。结果显示种植体间平均偏斜角度较小,侧位和额位分别为4.2°和5.3°,仅少数测量超过20°;种植体与就位道平均角度侧位9.3°、额位4.0°。回归分析表明种植体间距、翻瓣方案、插入扭矩和备洞深度与偏斜角度相关,无瓣手术和较短间距有利于提高平行度。

要点

  • 微型种植体间平均偏斜角侧位4.2°、额位5.3°,总体平行度良好。
  • 种植体与覆盖义齿就位道平均角度侧位9.3°、额位4.0°。
  • 无瓣手术、较短种植体间距、较高骨密度和较高插入扭矩与更好平行度相关。

核心结论

  • 微型种植体以低偏斜角度和满意平行度植入,无瓣手术、较短间距和较高骨密度有助于改善平行度。

研究设计与样本

  • 横断面研究,分析73例接受四枚一体式钛锆微型种植体的下颌覆盖义齿患者的CBCT扫描。

主要发现

  • 种植体间偏斜角度侧位0°至22.3°(均值4.2,SD=3.7),额位0°至26.2°(均值5.3,SD=4.1),p<.001。
  • 仅侧位1个(0.2%)、额位3个(0.7%)测量值超过20°。
  • 种植体与就位道平均角度侧位9.3°(SD=7.5)、额位4.0°(SD=2.9),p<.001。
  • 回归分析显示种植体偏斜与额位投影(p<.001)、配对种植体间距离较大(p=.017)、翻瓣手术(p=.002)、较高最终插入扭矩(p=.011)及较深针钻备洞(p<.001)显著相关。

临床怎么用

  • 临床可参考低偏斜角度结果,但需注意翻瓣、种植体间距和备洞深度对平行度的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors. METHODS: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post-insertion CBCT images in DICOM format were analyzed using the E-Vol-DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software. RESULTS: Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections (p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively (p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection (p < .001), greater distance between the paired implants (p = .017), the flapped surgical protocol (p = .002), higher final insertion torque (p = .011), and deeper preparation with the needle drill (p < .001). CONCLUSIONS: The mini-implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini-implants.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。