基于混合现实的动态导航系统辅助种植体植入:一项概念验证

Implant placement using mixed reality-based dynamic navigation: A proof of concept.
PubMed 文献 · J Dent · 2024-07-21

本研究首次在单牙缺失修复中临床应用新型混合现实动态导航(MR-DN)系统,流程包括口内扫描与锥形束CT数据采集、软件规划、全息引导植入及精度验证。手术从麻醉到缝合耗时30分钟,植入精度高,入口点三维距离0.417毫米,根尖三维偏差0.193毫米,角度差1.852°。结论表明MR-DN临床可行,但需大样本研究确认。

要点

  • MR-DN系统在单牙缺失种植中安全且省时,手术耗时30分钟。
  • 植入精度高:入口点三维距离0.417毫米,根尖三维偏差0.193毫米。
  • 角度差仅1.852°,显示导航系统定位准确。

核心结论

  • MR-DN系统在单牙缺失种植中临床可行,精度高且安全省时。

研究设计与样本

  • 概念验证研究,首次临床应用MR-DN系统于单牙缺失修复。

主要发现

  • 手术从麻醉到缝合耗时30分钟。
  • 入口点平面距离(XY)误差0.381毫米,入口点平面距离(Z)0.173毫米,入口点三维距离(En)0.417毫米。
  • 根尖三维偏差(An)0.193毫米,角度差1.852°。

临床怎么用

  • MR-DN可作为静态和动态引导手术技术的一种可能替代方案,用于单牙缺失修复。

局限性

  • 需大样本临床研究确认初步阳性结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To present the first clinical application of a novel mixed reality-based dynamic navigation (MR-DN) system in the rehabilitation of a single tooth gap. METHODS: The protocol consisted of the following: (1) three-dimensional patient data acquisition using intraoral scanning (IOS) and cone-beam computed tomography (CBCT), (2) implant planning using guided surgery software, (3) holography-guided implant placement using the novel MR-DN system (ANNA®, MARS Dental, Haifa, Israel) and (4) placement accuracy verification. RESULTS: The novel MR-DN system was safe and time-efficient, as the surgery took 30 min from anaesthesia to suturing. The accuracy of implant placement was high with minimal deviations recorded in the three planes of space compared to the presurgical planning: the error at the entry point planar distance (XY) was 0.381 mm, and the entry point planar distance (Z) was 0.173 mm, for a 3D entry point distance (En) of 0.417 mm. A 3D apex deviation (An) of 0.193 mm was registered, with an angle difference of 1.852° Conclusions: This proof-of-concept study demonstrated the clinical feasibility of MR-DN for guided implant placement in single tooth gaps. Further clinical studies on a large sample of patients are needed to confirm these positive preliminary results. Statement of clinical relevance: The use of MR-DN can change the perspectives of guided dental implant surgery as a possible alternative to the classic static and dynamic guided surgical techniques for the rehabilitation of single tooth gaps.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Shusterman A, Nashef R, Tecco S, et al. Implant placement using mixed reality-based dynamic navigation: A proof of concept. J Dent. 2024. PMID: 39043329. doi:10.1016/j.jdent.2024.105256

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。