荧光辅助放大技术用于根管再进入的微CT三维评估
本研究以30颗已行根管治疗的下颌第一磨牙为样本,采用微CT三维形态学分析,比较无放大、手术显微镜和REVEAL荧光放大装置辅助去除冠部修复体及颈部屏障后牙本质去除量与修复材料残留量。结果显示REVEAL组残留材料体积和牙本质去除百分比最优,提示荧光联合放大有助于根管再进入。
要点
- 荧光联合放大装置辅助下修复材料残留体积和牙本质去除百分比最低
- 显微镜组牙本质去除量与REVEAL组无统计学差异
- 肉眼组修复材料残留体积和牙本质去除百分比最差
核心结论
- 荧光联合放大技术是去除冠部修复体及颈部屏障后牙本质去除百分比更低、修复材料残留体积更小的最佳方法。
研究设计与样本
- 研究使用30颗已行根管治疗的下颌第一磨牙,经微CT扫描重建后行单尖充填并制作含0.1%荧光素的玻璃离子水门汀颈部屏障及树脂冠部修复体。
- 样本经20,000次热循环模拟老化后分为无放大、手术显微镜和REVEAL装置辅助三组(每组n=10),以金刚砂钻去除修复体及屏障。
- 去除后再次微CT扫描并与初始扫描叠加,用CTAn软件分析残留修复材料体积、牙本质去除体积及去除方向和部位,采用单因素方差分析(P < .05)。
主要发现
- REVEAL组残留材料体积为3.17 ± 1.65,牙本质去除百分比为2.56 ± 1.34。
- 显微镜组牙本质去除量为3.30 ± 1.48,与REVEAL组无统计学差异,残留材料体积与肉眼组统计学相似(9.63 ± 4.33)。
- 肉眼组残留材料体积(7.60 ± 2.68)和牙本质去除百分比(6.60 ± 3.70)结果最差。
临床怎么用
- 在根管再治疗中去除冠部修复体和颈部屏障时,可考虑使用荧光联合放大装置以减少牙本质去除和修复材料残留。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the volume of dentin removal and the volume of remnants of restorative material after the removal of an esthetic restorative coronal set and cervical barrier in endodontically treated mandibular molars with the aid of different magnification methods using 3-dimensional (3D) micro-computed tomographic (micro-CT) morphometric analysis. METHODS: A sample of 30 mandibular first molars (N = 30) was used. All teeth were endodontically treated, and the specimens were initially scanned using micro-CT imaging and reconstructed. The molars were filled by a single-cone technique, and immediately the material at the initial 2-mm cervical level was removed. Cervical barriers were confected using ionomer glass cement with fluorescein 0.1%, filling the 2 mm at the cervical level of the canals and an additional 2 mm as the base. The coronal restoration set was performed using esthetic resin composites. A simulated tooth aging process was performed with 20,000 thermocycling cycles. The sample was distributed into the following 3 groups (n = 10) for the removal of the restoration set and cervical barrier with diamond burs based on the magnification aid: no magnification aid (naked eye), operative microscope aid, and REVEAL device (Design for Vision Inc, Bohemia, NY) aid. After removal, the final 3D micro-CT scanning and reconstruction were conducted with the same parameters as the initial scanning, and superposition of the final and initial scanning was performed. Morphometric analysis was conducted using CTAn software (Bruker microCT, Kontich, Belgium) to assess the volume of remnant restorative material (mm³), the volume of dentin removal (mm³), and the direction and site of dentin removal. Data were analyzed using 1-Way analysis of variance (P < .05). RESULTS: The REVEAL group showed better results regarding the volume of remnant material (3.17 ± 1.65) and the percentage of dentin removal (2.56 ± 1.34). The microscope group showed no statistical difference compared with the REVEAL group regarding dentin removal (3.30 ± 1.48) and was statistically similar to the naked eye group in the volume of remnant material (9.63 ± 4.33). The naked eye group showed the worst results for the volume of remnant material (7.60 ± 2.68) and the percentage of dentin removal (6.60 ± 3.70). CONCLUSIONS: The use of fluorescence associated with magnification was the method that presented the best results, with lower percentages of dentin removal and smaller volumes of remaining restorative material. This is an innovative technology in endodontics that shows potential to overcome the challenge of reaccessing root canals in the context of endodontic retreatment.
引用
- Ramirez I, Altube LG, Camargo RV, et al. A Fluorescence-based Method to Reaccess Root Canals in Endodontically Treated Teeth: A Micro-Computed Tomography Tridimensional Assessment. J Endod. 2024. PMID: 39038534. doi:10.1016/j.joen.2024.07.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。