冲洗针设计对根管消毒与清洁效果的影响
该离体研究将人下颌磨牙近中根按micro-CT解剖匹配后分为三组,比较开放平头针、闭合侧开孔针和TruNatomy塑料针在2.5%次氯酸钠冲洗下的抗菌与清洁效果。结果显示三组在整体及根尖段细菌减少量、硬组织碎屑累积上均无显著差异,但开放平头针在根尖段(含峡部)细菌qPCR阴性的标本数显著多于TruNatomy。
要点
- 三种冲洗针在适当插入深度下抗菌与清洁效果相似。
- 开放平头针在根尖段含峡部区域获得更多细菌阴性标本。
- 针头尺寸、冲洗液类型、用量和流速需控制一致。
核心结论
- 三种冲洗针设计在控制针头尺寸、冲洗液类型、用量和流速等变量时,抗菌和清洁性能相似。
- 开放平头针在根尖段(含峡部)细菌qPCR阴性的标本数显著多于TruNatomy针(P < .05)。
研究设计与样本
- 离体研究,使用按micro-CT解剖匹配的离体下颌磨牙近中根(Vertucci II型),每组18个。
- 根管用混合细菌培养物污染30天,随后用2.5%次氯酸钠配合三种冲洗针进行预备。
主要发现
- 三组从S1到S2细菌计数均大幅减少:开放平头针组99.95%、闭合侧开孔针组98.93%、TruNatomy针组98.90%(P < .01)。
- 三组在整体根管和根尖段的细菌减少量均无显著差异(P > .05)。
- 三组硬组织碎屑累积量无显著差异(P > .05)。
- 开放平头针组在S3(根尖段)qPCR细菌阴性的标本数显著多于TruNatomy组(P < .05)。
关键数值与推荐
- 开放平头针插入深度为距工作长度3 mm,闭合侧开孔针和TruNatomy针均为距工作长度1 mm。
- 冲洗液为2.5%次氯酸钠。
临床怎么用
- 临床使用冲洗针时需控制针头尺寸、冲洗液类型、用量和流速等变量。
- 若关注根尖段及峡部的细菌清除,开放平头针可能获得更多细菌阴性结果。
局限性
- 离体研究,结果需结合临床进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This ex vivo study evaluated the disinfecting and cleaning effects of root canal preparation using sodium hypochlorite irrigation with 3 different needle designs. METHODS: Mesial roots from extracted mandibular molars with Vertucci class II configuration were anatomically matched based on micro-computed tomography (micro-CT) analyses and distributed into 3 groups (n = 18/group). The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation using 2.5% sodium hypochlorite irrigation with open-ended flat needle (3 mm short of the working length - WL), closed-ended side-vented irrigation needle (1 mm short of the WL), or a closed-ended plastic needle with 2 lateral outlets (TruNatomy) (1 mm short of the WL). Bacteriological samples were taken from the canals before (S1) and after preparation (S2). After another micro-CT scan, the roots were sectioned and samples were also taken from the apical canal segment (S3). Bacterial reduction was assessed by quantitative real-time polymerase chain reaction. The amount of accumulated hard tissue debris was evaluated by micro-CT. RESULTS: A substantial reduction in bacterial counts was observed in all 3 groups when comparing S1 with S2 (99.95%, 98.93%, and 98.90% in the open-ended, closed-ended, and TruNatomy needle groups, respectively) (P < .01). No significant differences were observed between groups for bacterial reduction in the full and apical canal (P > .05). There were no intergroup differences in the amount of accumulated hard tissue debris either (P > .05). The open-ended needle group showed significantly more specimens with quantitative real-time polymerase chain reaction negative results for bacteria in S3 than TruNatomy (P < .05). CONCLUSION: When used up to an appropriate insertion depth, the 3 needle types result in similar antibacterial and cleaning performance, provided variables such as needle size and irrigant type, volume and flow rate are controlled. Exclusive analysis of the apical segment, including the isthmus, revealed that the open-ended needle yielded more cases negative for bacteria.
引用
- Baasch A, Campello AF, Rodrigues RCV, et al. Effects of the Irrigation Needle Design on Root Canal Disinfection and Cleaning. J Endod. 2024. PMID: 39029891. doi:10.1016/j.joen.2024.07.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。