文献速递牙体牙髓病口腔修复与种植

根管冲洗剂对温和型通用粘接剂牙本质剪切粘接强度的影响

Effects of Endodontic Irrigants on Shear Bond Strength of Mild Universal Adhesives to Dentin.
PubMed 文献 · J Endod · 2024-07-07

该体外研究评估了5种通用粘接剂在牙本质经6%次氯酸钠(NaOCl)及NaOCl后17%EDTA处理后的剪切粘接强度(SBS)。自酸蚀模式下,NaOCl暴露显著降低SBS(P < .05),但后续EDTA处理可消除此负面影响;全酸蚀模式下结果因粘接剂而异。

要点

  • 自酸蚀模式:NaOCl显著降低通用粘接剂SBS,EDTA处理后恢复至对照水平或更高。
  • 全酸蚀模式:仅Prime & Bond Active受NaOCl显著影响,其他粘接剂表现不一。
  • 临床使用自酸蚀通用粘接剂前,NaOCl冲洗后建议使用EDTA以维持粘接强度。

核心结论

  • 对于所测试的粘接剂,在NaOCl暴露后使用17%EDTA可消除NaOCl对自酸蚀模式SBS的负面影响。
  • 全酸蚀模式下结果差异显著,部分粘接剂性能因具体测试条件而异。

研究设计与样本

  • 体外研究,评估5种通用粘接剂(Adhese Universal、Scotchbond Universal、Prime & Bond Elect、Prime & Bond Active、Optibond XTR)的SBS。

主要发现

  • 自酸蚀模式下,牙本质暴露于6% NaOCl后所有粘接剂SBS显著降低(P < .05)。
  • 自酸蚀模式下,NaOCl后17% EDTA处理使SBS等于或高于阴性对照(P < .05)。
  • 全酸蚀模式下,仅Prime & Bond Active受NaOCl显著影响(P < .05)。
  • 全酸蚀模式下,Adhese Universal受NaOCl+EDTA负面影响(P < .05)。
  • 全酸蚀模式下,Prime & Bond Elect在NaOCl+EDTA后SBS低于仅NaOCl暴露(P < .05),但与阴性对照无差异。

关键数值与推荐

  • NaOCl浓度6%,暴露时间20分钟;EDTA浓度17%,暴露时间1分钟。
  • 自酸蚀模式SBS降低及EDTA恢复效应均以P < .05为显著性标准。

临床怎么用

  • 使用自酸蚀通用粘接剂时,若牙本质经NaOCl冲洗,建议后续使用17% EDTA处理以维持粘接强度。
  • 全酸蚀模式下粘接剂选择需考虑冲洗方案,部分粘接剂可能受NaOCl或EDTA影响。

局限性

  • 体外研究,结果不能直接等同于临床长期粘接效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The objective of this in vitro study was to evaluate the shear bond strength (SBS) of several universal adhesives to dentin treated with sodium hypochlorite (NaOCl), and NaOCl followed by ethylenediaminetetraacetic acid (EDTA). MATERIALS AND METHODS: Adhese Universal, Scotchbond Universal, Prime & Bond Elect, Prime & Bond Active, and Optibond XTR were included in the study. SBS values were determined in self-etch mode with no pretreatment of the dentin, after a 20-minute exposure of the dentin to 6% NaOCl, and after a 20-minute exposure to NaOCl followed by a one-minute exposure to 17% EDTA. Experimental groups were repeated using a total-etch technique (except Optibond XTR). RESULTS: Adhesives in self-etch mode had significantly reduced SBS following dentin exposure to NaOCl (P < .05), while with a total-etch technique, only Prime & Bond Active was affected (P < .05). SBS in self-etch mode when NaOCl exposure was followed by EDTA were equal to or higher than negative control values (P < .05). For total-etch groups, Adhese Universal was negatively affected by NaOCl + EDTA exposure (P < .05). Prime & Bond Elect exhibited lower SBS following NaOCl + EDTA exposure when compared to just NaOCl exposure but was not different from the negative control (P < .05). CONCLUSION: For the adhesives tested, the use of 17% EDTA following NaOCl exposure negated the negative effects of NaOCl on SBS in self-etch mode. When used in total-etch mode, results varied significantly, with some adhesives performing better or worse depending on the specific testing condition.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Stevens CD, Schiffenhaus S. Effects of Endodontic Irrigants on Shear Bond Strength of Mild Universal Adhesives to Dentin. J Endod. 2024. PMID: 38981558. doi:10.1016/j.joen.2024.07.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。