文献速递口腔修复与种植

钛成品基台与钴铬个性化基台的微间隙体外比较

Comparative in vitro evaluation of microgap in titanium stock versus cobalt-chrome custom abutments on a conical connection implant: Effect of crown cementation and ceramic veneering.
PubMed 文献 · Clin Oral Implants Res · 2024-06-17

该体外研究比较了CAD/CAM铣削或激光烧结钴铬个性化基台与钛成品基台在有无冠粘接及陶瓷饰面下的种植体-基台连接微间隙。六组共36个样本经30 Ncm扭矩拧紧后沿长轴切开,用扫描电镜测量微间隙。结果显示钛成品基台微间隙小于钴铬个性化基台,冠粘接和陶瓷饰面未显著改变微间隙。

要点

  • 钛成品基台微间隙小于钴铬个性化基台。
  • 冠粘接与陶瓷饰面未显著改变微间隙。
  • 所有组最大微间隙位于上部水平。

核心结论

  • 钛成品基台比钴铬个性化基台提供更紧密的配合。
  • 冠粘接和陶瓷饰面未导致种植体-基台连接微间隙显著变化。

研究设计与样本

  • 体外研究,六组每组六个基台,共36个样本。
  • 基台以30 Ncm扭矩拧紧至种植体,沿长轴切开后用扫描电镜测量微间隙。
  • 数据采用Kruskal-Wallis检验(p < .05)。

主要发现

  • 微间隙均值(μm):STK 0.54 ± 0.44,STK-Z 0.55 ± 0.48,MIL 1.53 ± 1.30,MIL-C 2.30 ± 2.2,SIN 1.53 ± 1.37,SIN-C 1.87 ± 1.8。
  • STK和STK-Z组与其他组间存在显著差异(p < .05)。
  • 铣削与激光烧结组在陶瓷饰面前后均无显著差异。
  • 所有组最大微间隙均位于上部水平。

临床怎么用

  • 选择基台时需权衡钛成品基台的更紧密配合与钴铬个性化基台的个性化需求。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the implant-abutment connection microgap between computer-aided design and computer-aided manufacturing (CAD/CAM) milled or laser-sintered cobalt-chrome custom abutments with or without ceramic veneering and titanium stock abutments with or without crown cementation. MATERIAL AND METHODS: Six groups of six abutments each were prepared: (1) CAD/CAM cobalt-chrome custom abutments: milled, milled with ceramic veneering, laser-sintered, and laser-sintered with ceramic veneering (four groups: MIL, MIL-C, SIN, and SIN-C, respectively) and (2) titanium stock abutments with or without zirconia crown cementation (two groups: STK and STK-Z, respectively). Abutments were screwed to the implants by applying 30 Ncm torque. All 36 samples were sectioned along their long axes. The implant-abutment connection microgap was measured using scanning electron microscopy on the right and left sides of the connection at the upper, middle, and lower levels. Data were analyzed using the Kruskal-Wallis test (p < .05). RESULTS: Mean values (μm) of the microgap were 0.54 ± 0.44 (STK), 0.55 ± 0.48 (STK-Z), 1.53 ± 1.30 (MIL), 2.30 ± 2.2 (MIL-C), 1.53 ± 1.37 (SIN), and 1.87 ± 1.8 (SIN-C). Although significant differences were observed between the STK and STK-Z groups and the other groups (p < .05), none were observed between the milled and laser-sintered groups before or after ceramic veneering. The largest microgap was observed at the upper level in all groups. CONCLUSIONS: Titanium stock abutments provided a closer fit than cobalt-chrome custom abutments. Neither crown cementation nor ceramic veneering resulted in significant changes in the implant-abutment connection microgap.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Herrero-Climent F, Martínez-Rus F, Salido MP, et al. Comparative in vitro evaluation of microgap in titanium stock versus cobalt-chrome custom abutments on a conical connection implant: Effect of crown cementation and ceramic veneering. Clin Oral Implants Res. 2024. PMID: 38884385. doi:10.1111/clr.14317

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。