文献速递口腔修复与种植

口内扫描STL与CBCT叠加对动态导航系统性能影响的体外研究

The effect on the performance of a dynamic navigation system of superimposing a standard tessellation language (STL) file obtained with an intraoral scan on a cone beam computer tomograph (CBCT). An experimental in vitro study.
PubMed 文献 · J Dent · 2024-06-22

结果显示CBCT+STL组三维平台偏差显著低于CBCT组(平均差0.17 mm,95%CI 0.01-0.23,P=0.039),其余精度指标和手术时间两组相似。结论认为叠加口内扫描可轻微减少偏差,但临床意义存疑。

要点

  • CBCT+STL组三维平台偏差显著低于CBCT组(平均差0.17 mm,P=0.039)。
  • 角度偏差、平台侧向偏差、根尖全局偏差、根尖深度偏差及手术时间两组无显著差异。
  • 叠加口内扫描在放射伪影存在时可能有用,但整体精度提升临床意义存疑。

核心结论

  • 引入口内扫描STL似乎能轻微减少dCAIS系统种植体植入的偏差,但该改善的临床影响存疑。
  • 叠加口内扫描于CBCT图像似乎不增加dCAIS系统的精度,但在存在放射伪影时可能有用。

研究设计与样本

  • CBCT+STL组将CBCT文件与口内扫描STL文件叠加用于配准;CBCT组仅使用CBCT图像配准。
  • 通过追踪CBCT或STL图像上的基准点进行解剖配准,术前术后CBCT重叠评估种植体植入精度。

主要发现

  • CBCT+STL组三维平台偏差均值0.71 mm(SD 0.29),CBCT组均值0.88 mm(SD 0.39),平均差0.17 mm(95%CI 0.01-0.23,P=0.039)。
  • 角度偏差平均差-0.01,平台侧向偏差平均差0.08 mm,根尖全局偏差平均差0.01 mm,根尖深度偏差平均差0.33 mm,组间P>0.05。
  • 手术时间平均差3.383 min,组间P>0.05。

临床怎么用

  • 在dCAIS系统中,叠加口内扫描STL文件可轻微降低三维平台偏差,但整体精度提升有限。
  • 当CBCT图像存在放射伪影时,可考虑叠加口内扫描STL辅助配准。

局限性

  • 研究为体外树脂模型实验,结果外推到临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the accuracy and operative time of implant placement using a dynamic computer assisted implant surgery (dCAIS) system based on a cone beam computer tomography (CBCT) image, with and without superimposing a standard tessellation language (STL) file of an intraoral scan of the patient. METHODS: Ten identical resin models simulating an upper maxilla with posterior edentulism were assigned to two groups. In the CBCT+STL group, a CBCT file and an intraoral STL file were superimposed and used for registration; in the CBCT group, registration was performed using CBCT images. Six implants were placed in each model using the Navident® dynamic navigation system. Anatomy registration was performed by tracing fiducial points on the CBCT or STL image, depending on the group. Preoperative and postoperative CBCT images were overlaid to assess implant placement accuracy. RESULTS: Sixty implants were analyzed (30 implants in each group). 3D platform deviation was significantly lower (mean difference (MD): 0.17 mm; 95 % confidence interval (CI): 0.01 to 0.23; P = 0.039) in the CBCT+STL group (mean: 0.71 mm; standard deviation (SD): 0.29) than in the CBCT group (mean: 0.88 mm; SD: 0.39). The remaining accuracy outcome variables (angular deviation MD: -0.01; platform lateral deviation MD: 0.08 mm; apex global MD: 0.01 mm; apex depth MD: 0.33 mm) and surgery time (MD: 3.383 min.) were similar in both groups (p > 0.05). CONCLUSIONS: The introduction of an intraoral scan (STL) seems to reduce deviations slightly in dental implant placement with dCAIS systems. However, the clinical repercussion of this improvement is questionable. CLINICAL SIGNIFICANCE: Superimposing an intraoral scan on the CBCT image does not seem to increase the accuracy of dCAIS systems but can be useful when radiographic artifacts are present.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Jorba-García A, Ruiz-Romero V, Bara-Casaus JJ, et al. The effect on the performance of a dynamic navigation system of superimposing a standard tessellation language (STL) file obtained with an intraoral scan on a cone beam computer tomograph (CBCT). An experimental in vitro study. J Dent. 2024. PMID: 38909646. doi:10.1016/j.jdent.2024.105150

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。