超声诊断种植体周围骨缺损:天然人类下颌骨体外研究
本研究在5例人类下颌骨上植入27枚种植体并制备骨缺损,比较牙周探针直接测量、24-MHz超声与数字容积断层(DVT)的测量结果;超声与直接测量及DVT均呈强相关,超声对开裂型骨缺损测量精度最高。
要点
- 超声可识别并测量种植体周围骨缺损,与直接测量和DVT强相关。
- 超声测量精度:开裂型>开窗型>三壁骨缺损。
- 超声与直接测量平均差异0.41 mm(95%CI -0.47至1.29)。
核心结论
- 所有种植体周围骨缺损均可被超声识别并测量,超声测量与直接测量及DVT测量呈强相关。
- 超声测量精度对开裂型骨缺损最高,其次为开窗型,三壁骨缺损最低。
研究设计与样本
- 在5例天然人类下颌骨上植入27枚种植体,标准化制备开裂型14处、开窗型7处、三壁骨缺损6处。
- 使用牙周探针直接测量、24-MHz临床超声探头检查及DVT影像评估,计算均值与标准差。
- 采用Pearson相关系数与Bland-Altman分析进行统计学比较。
主要发现
- 骨缺损平均尺寸:直接测量3.22±1.58 mm,超声2.90±1.47 mm,DVT 2.99±1.52 mm。
- 直接测量与超声平均差异0.41 mm(95%CI -0.47至1.29),超声与DVT平均差异0.33 mm(95%CI -0.30至0.97),直接测量与DVT平均差异0.28 mm(95%CI -0.50至1.07)。
临床怎么用
- 超声可作为种植体周围骨缺损的辅助测量手段,尤其对开裂型骨缺损测量精度较高。
- 超声测量结果与DVT及直接测量强相关,但存在一定平均差异,临床解读需结合其他检查。
局限性
- 研究为体外天然人类下颌骨研究,样本量为5例下颌骨、27枚种植体。
- 骨缺损为标准制备,可能不完全代表临床实际缺损形态。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3-wall bone defects on implants. MATERIALS AND METHODS: The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3-wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24-MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Bone defects were on average 3.22 ± 1.58 mm per direct measurement, 2.90 ± 1.47 mm using US, and 2.99 ± 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (-0.47 to 1.29), US and DVT 0.33 (-0.30 to 0.97), and direct and DVT 0.28 (-0.50 to 1.07). CONCLUSION: All peri-implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3-wall bone defects.
引用
- Bykhovsky I, Hildner A, Kripfgans OD, et al. Sonography in the diagnosis of peri-implant bone defects: An in vitro study on native human mandibles. Clin Oral Implants Res. 2024. PMID: 38837465. doi:10.1111/clr.14302
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。